Characterisation of the physical performance of the new integrated PET/CT system Discovery ST (GE Medical Systems) has been performed following the NEMA NU 2-1994 (N-94) and the NEMA NU 2-2001 (N-01) standards in both 2D and 3D acquisition configuration. The Discovery ST combines a four or eight multi-slice helical CT scanner with a PET tomograph which consists of 10,080 BGO crystals arranged in 24 rings. The crystal dimensions are 6.3 x 6.3 x 30 mm(3) and they are organised in blocks of 6 x 6 crystals, coupled to a single photomultiplier tube with four anodes. The 24 rings of the PET system allow 47 images to be obtained, spaced by 3.27 mm, and covering an axial field of view of 157 mm. The low- and high-energy thresholds are set to 375 and 650 keV, respectively. The coincidence time window is set to 11.7 ns. Using the NEMA N-94 standard, the main results were: (1) the average (radial and tangential) transverse spatial resolution (FWHM) at 1, 10 and 20 cm off axis was 6.28 mm, 7.09 mm and 7.45 mm in 2D, and 6.68 mm, 7.72 mm and 8.13 mm in 3D; (2) the sensitivity for true events was 8,567 cps/kBq/cc in 2D and 36,649 cps/kBq/cc in 3D; (3) the scatter fraction was 15% in 2D and 30% in 3D; (4) the peak true events rate, the true events rate at 50% of the system dead-time and the true events rate when equal to the random events rate were 750 kcps at 189.81 kBq/cc, 744 kcps at 186.48 kBq/cc and 686 kcps at 150.59 kBq/cc, respectively, in 2D, and 922 kcps at 44.03 kBq/cc, 834 kcps at 53.28 kBq/cc and 921 kcps at 44.03 kBq/cc in 3D; (5) the noise equivalent count (NEC) peak rate was 270 kcps at 34.38 kBq/cc in 3D, with random coincidences estimated by delayed events. Using the NEMA N-01 standards the main results were: (1) the average transverse and axial spatial resolution (FWHM) at 1 cm and 10 cm off axis was 6.28 (4.56) mm and 6.88 (6.11) mm in 2D, and 6.29 (5.68) mm and 6.82 (6.05) mm in 3D; (2) the average sensitivity for the two radial positions (r=0 cm and r=10 cm) was 1.93 cps/kBq in 2D and 9.12 cps/kBq in 3D; (3) the scatter fraction was 19% in 2D and 45% in 3D; (4) the NEC peak rate was 54 kcps at 46.99 kBq/cc in 2D and 45.5 kcps at 10.84 kBq/cc in 3D, when random coincidences were estimated by using k=2 in the NEC formula, while the NEC peak rate was 81 kcps at 64.43 kBq/cc and 66 kcps at 14.86 kBq/cc in 2D and 3D, respectively, when random coincidences were estimated by using k=1 in the NEC formula. The new integrated PET-CT system Discovery ST has good overall performances in both 2D and 3D, with in particular a high sensitivity and a very good 3D NEC response.
18 F-labeled fluoroazomycinarabinoside ( 18 F-FAZA) is a PET biomarker for noninvasive identification of regional tumor hypoxia. The aim of the present phase I study was to evaluate the biodistribution and dosimetry of 18 F-FAZA in non-small cell lung cancer patients. Methods: Five patients awaiting surgical resection of histologically proven or radiologically suspected non-small cell lung cancer were prospectively enrolled in the study. The patients underwent PET/CT after injection of 371 6 32 MBq of 18 F-FAZA. The protocol consisted of a 10-min dynamic acquisition of the heart to calculate the activity in blood, followed by 4 whole-body PET/CT scans, from the vertex to the mid thigh, at 10, 60, 120, and 240 min after injection. Urine samples were collected after each imaging session and at 360 min after injection. Volumes of interest were drawn around visually identifiable source organs to generate time-activity curves. Residence times were determined from time-activity curves, and effective doses to individual organs and the whole body were calculated using OLINDA/EXM 1.2 for the standard male and female phantoms. Results: Blood clearance was characterized by a rapid distribution followed by first-order elimination. The highest uptake was in muscle and liver, with respective percentage injected activity (%IA) peaks of 42.7 6 5.3 %IA and 5.5 6 0.6 %IA. The total urinary excretion was 15 %IA. The critical organ, with the highest absorbed radiation doses, was the urinary bladder wall, at 0.047 6 0.008 and 0.067 6 0.007 mGy/ MBq for the 2-and 4-h voiding intervals, respectively. The effective doses for the standard male and female phantoms were 0.013 6 0.004 and 0.014 6 0.004 mSv/MBq, respectively, depending on the voiding schedule. Conclusion: With respect to the available literature, the biodistribution of 18 F-FAZA in humans appeared to be slightly different from that in mice, with a low clearance in humans. Therefore, use of animal data may moderately underestimate radiation doses to organs in humans. Our dosimetry data showed that a 370-MBq injection of 18 F-FAZA is safe for clinical use, similar to other widely used PET ligands. In particular, the effective dose is not appreciably different from those obtained with other hypoxia tracers, such as 18 F-fluoromisonidazole.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.