Benzophenone-3 (BZ-3) is a commonly used, chemical UV-absorber. It has been used for many years to protect against UV-radiation. Previous studies have shown that BZ-3 penetrates the skin, and it can be found in urine, faeces, and blood. In this study we examined the percutaneous absorption of BZ-3. The amount of BZ-3 absorbed was measured in urine, as experimental studies in the rat have shown that urine is the major route of excretion. Eleven volunteers applied the recommended amount of a commercially available sunscreen and urine samples were collected during a 48-h period after application. The average total amount excreted was 11 mg, median 9.8 mg, which is approximately 0.4% of the applied amount of BZ-3. Some of the volunteers still excreted BZ-3 48 h after application. It is evident that BZ-3 undergoes conjugation in the body to make it water soluble. However, we do not know at what age the ability to conjugate is fully developed, and therefore for children physical filters such as titanium dioxide and/or zinc oxide might still be considered a more appropriate sunscreen component.
Background:Benzophenone-3 (BZ-3) is a common ultraviolet (UV) absorbing compound in sunscreens. It is the most bioavailable species of all UV-absorbing compounds after topical application and can be found in plasma and urine.Objectives:The aim of this study was to develop a reverse-phase high performance liquid chromatography (HPLC) method for determining the amounts BZ-3 and its metabolite 2,4-dihydroxybenzophenone (DHB) in human urine. The method had to be suitable for handling a large number of samples. It also had to be rapid and simple, but still sensitive, accurate and reproducible. The assay was applied to study the urinary excretion pattern after repeated whole-body applications of a commercial sunscreen, containing 4% BZ-3, to 25 healthy volunteers.Methods:Each sample was analyzed with regard to both conjugated/non-conjugated BZ-3 and conjugated/non-conjugated DHB, since both BZ-3 and DHB are extensively conjugated in the body. Solid-phase extraction (SPE) with C8 columns was followed by reverse-phase HPLC. For separation a Genesis C18 column was used with an acethonitrile-water mobile phase and the UV-detector was set at 287 nm.Results:The assay was linear r2 > 0.99, with detection limits for BZ-3 and DHB of 0.01 μmol L−1 and 0.16 μmol L−1 respectively. Relative standard deviation (RSD) was less than 10% for BZ-3 and less than 13% for DHB. The excretion pattern varied among the human volunteers; we discerned different patterns among the individuals.Conclusions:The reverse-phase HPLC assay and extraction procedures developed are suitable for use when a large number of samples need to be analyzed and the method fulfilled our objectives. The differences in excretion pattern may be due to differences in enzyme activity but further studies, especially about genetic polymorphism, need to be performed to verify this finding.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.