A combined approach of inhalation device and vaccine formulation development is essential. This should result in a system that can effectively be used by the target population and can be produced at low costs. Only then, this challenging administration route can be successfully applied to large-scale vaccination programs.
Fine excipient particles or ‘fines’ have been shown to improve the dispersion performance of carrier-based formulations for dry powder inhalation. Mechanistic formulation studies have focussed mainly on explaining this positive effect. Previous studies have shown that higher drug contents may cause a decrease in dispersion performance, and there is no reason why this should not be true for fines with a similar shape, size and cohesiveness as drug particles. Therefore, the effects on drug detachment of ‘fine lactose fines’ (FLF, X50 = 1.95 µm) with a similar size and shape as micronised budesonide were studied and compared to those of ‘coarse lactose fines’ (CLF, X50 = 3.94 µm). Furthermore, interactions with the inhalation flow rate, the drug content and the mixing order were taken into account. The observed effects of FLF are comparable to drug content effects in that the detached drug fraction was decreased at low drug content and low flow rates but increased at higher flow rates. At high drug content the effects of added FLF were negligible. In contrast, CLF resulted in higher detached drug fractions at all flow rates and drug contents. The results from this study suggest that the effects of fines may be explained by two new mechanisms in addition to those previously proposed. Firstly, fines below a certain size may increase the effectiveness of press-on forces or cause the formation of strongly coherent fine particle networks on the carrier surface containing the drug particles. Secondly, when coarse enough, fines may prevent the formation of, or disrupt such fine particle networks, possibly through a lowering of their tensile strength. It is recommended that future mechanistic studies are based on the recognition that added fines may have any effect on dispersion performance, which is determined by the formulation and dispersion conditions.
Age appropriateness is a major concern of pulmonary delivery devices, in particular of dry powder inhalers (DPIs), since their performance strongly depends on the inspiratory flow manoeuvre of the patient. Previous research on the use of DPIs by children focused mostly on specific DPIs or single inspiratory parameters. In this study, we investigated the requirements for a paediatric DPI more broadly using an instrumented test inhaler. Our primary aim was to assess the impact of airflow resistance on children’s inspiratory flow profiles. Additionally, we investigated children’s preferences for airflow resistance and mouthpiece design and how these relate to what may be most suitable for them. We tested 98 children (aged 4.7–12.6 years), of whom 91 were able to perform one or more correct inhalations through the test inhaler. We recorded flow profiles at five airflow resistances ranging from 0.025 to 0.055 kPa0.5.min.L−1 and computed various inspiratory flow parameters from these recordings. A sinuscope was used to observe any obstructions in the oral cavity during inhalation. 256 flow profiles were included for analysis. We found that both airflow resistance and the children’s characteristics affect the inspiratory parameters. Our data suggest that a medium-high resistance is both suitable for and well appreciated by children aged 5–12 years. High incidences (up to 90%) of obstructions were found, which may restrict the use of DPIs by children. However, an oblong mouthpiece that was preferred the most appeared to positively affect the passageway through the oral cavity. To accommodate children from the age of 5 years onwards, a DPI should deliver a sufficiently high fine particle dose within an inhaled volume of 0.5 L and at a peak inspiratory flow rate of 25–40 L.min−1. We recommend taking these requirements into account for future paediatric inhaler development.
Historically, the inhaled route has been used for the delivery of locally-acting drugs for the treatment of respiratory conditions, such as asthma, COPD, and airway infections. Targeted delivery of substances to the lungs has some key advantages over systemic administration, including a more rapid onset of action, an increased therapeutic effect, and, depending on the agent inhaled, reduced systemic side effects since the required local concentration in the lungs can be obtained with a lower dose. Fortunately, when designed properly, inhaled drug delivery devices can be very effective and safe for getting active agents directly to their site of action.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.