Purpose:To develop low-dose thin-section computed tomographic (CT) protocols for assessment of cystic fi brosis (CF) in pediatric patients and determine the clinical usefulness thereof compared with chest radiography.
Materials and Methods:After institutional review board approval and informed consent from patients or guardians were obtained, 14 patients with CF and 11 patients without CF (16 male, nine female; mean age, 12.6 years 6 5.4 [standard deviation]; range, 3.5-25 years) who underwent imaging for clinical reasons underwent low-dose thin-section CT. Sections 1 mm thick (protocol A) were used in 10 patients, and sections 0.5 mm thick (protocol B) were used in 15 patients at six levels at 120 kVp and 30-50 mA. Image quality and diagnostic acceptability were scored qualitatively and quantitatively by two radiologists who also quantifi ed disease severity at thin-section CT and chest radiography. Effective doses were calculated by using a CT dosimetry calculator.
Results:Low-dose thin-section CT was performed with mean effective doses of 0.19 mSv 6 0.03 for protocol A and 0.14 mSv 6 0.04 for protocol B ( P , .005). Diagnostic acceptability and depiction of bronchovascular structures at lung window settings were graded as almost excellent for both protocols, but protocol B was inferior to protocol A for mediastinal assessment ( P , .02). Patients with CF had moderate lung disease with a mean Bhalla score of 9.2 6 5.3 (range, 0-19), compared with that of patients without CF (1.1 6 1.4; P , .001). There was excellent correlation between thin-section CT and chest radiography ( r = 0.88-0.92; P , .001).
Conclusion:Low-dose thin-section CT can be performed at lower effective doses than can standard CT, approaching those of chest radiography. Low-dose thin-section CT could be appropriate for evaluating bronchiectasis in pediatric patients, yielding appropriate information about lung parenchyma and bronchovascular structures.
Accurate estimation of gas volumes on CT is possible using threshold-based segmentation software with a wide range of upper thresholds. The optimal upper threshold for estimation of small volumes (1-6 mL) was -550 HU and -350 HU for volumes of 10-50 mL.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.