Background: Coronavirus Disease 2019 (COVID-19) patients often present with thromboembolic events. In COVID-19 patients, routine hemostatic assays cannot correctly identify patients at risk for thromboembolic events. Viscoelastic testing with rotational thromboelastometry (ROTEM) might improve the characterization of COVID-19-associated coagulopathy.Objective: To unravel underlying coagulopathy and fibrinolysis over time as measured by serial assessment heparin-independent (FIBTEM and EXTEM) and fibrinolysis illustrating (tissue plasminogen activator; tPA) ROTEM assays.Patients/Methods: Between April 23 and June 12, consecutive adult patients enrolled within the Maastricht Intensive Care COVID (MaastrICCht) cohort were included, and a comprehensive set of clinical, physiological, pharmaceutical, and laboratory variables were collected daily. Twice per week, EXTEM, FIBTEM, and tPA ROTEM were performed. Clotting time (CT), clot formation time (CFT), maximum clot firmness (MCF), lysis onset time (LOT), and lysis time (LT) were determined to assess clot development and breakdown and were compared to routine hemostatic assays.Results: In 36 patients, 96 EXTEM/FIBTEM and 87 tPA ROTEM tests were performed during a 6-week follow-up. CT prolongation was present in 54% of EXTEM measurements, which were not matched by prothrombin time (PT) in 37%. Respectively, 81 and 99% of all EXTEM and FIBTEM MCF values were above the reference range, and median MCF remained elevated during follow-up. The ROTEM fibrinolysis parameters remained prolonged with median LOT consequently >49 min and unmeasurable LT in 56% of measurements, suggesting a severe hypofibrinolytic phenotype.Conclusion: ROTEM tests in COVID-19 ICU patients show hypercoagulability and severe hypofibrinolysis persisting over at least 6 weeks.
Introduction Severe acute respiratory syndrome coronavirus 2 (SARS-CoV2) infection is associated with a clear prothrombotic phenotype. Although the exact pathophysiological mechanisms are not yet fully understood, thrombosis is clearly a highly important in the prognosis and outcome of COVID-19. As such, there is a need for diagnostic analysis and quantification of the coagulation potential in these patients, both at diagnosis and follow-up. Global coagulation assays like thrombin generation (TG) and rotational thromboelastometry (ROTEM) might be suitable in estimating COVID-19 associated coagulopathy and thrombosis risk. Therefore, we aimed at validating both assays for samples with high levels of fibrinogen and in the presence of anticoagulant heparins, such as commonly observed for COVID-19 ICU patients. Materials and methods Calibrated Automated Thrombography (CAT) was optimized to assess plasma thrombin generation in the presence of heparins. The final conditions with either 10 μg/mL Ellagic acid (EA) or PPP Reagent HIGH (high tissue factor; HPPH) were validated according to the EP5 protocol for within-run and between-run variability. Overall variability was well below 10%. To estimate the influences of heparins and high fibrinogen levels, CAT was performed on spiked plasma aliquots from 13 healthy volunteers. Comparable to the CAT method, tPA-ROTEM was used to validate the effect of high fibrinogen and heparins on clotting time, clot firmness and clot lysis parameters. Results Our adjusted COVID-19 assay showed a heparin dose dependent decrease in peak height and endogenous thrombin potential (ETP) for both EA and HPPH triggered variants. High fibrinogen did not alter the inhibitory effect of either LMWH or UFH, nor did it influence the peak height or ETP in any of the conditions. The tPA-ROTEM showed a significant prolongation in clotting time with the additions of heparin, which normalized with the addition of high fibrinogen. MCF was markedly increased in all hyperfibrinogenemic conditions. A trend towards increased lysis time and, thus, decreased fibrinolysis was observed. Conclusion Thrombin generation and tPA-ROTEM protocols for measurements in the COVID-19 populations were adjusted and validated. The adjusted thrombin generation assay shows good sensitivity for measurements in heparin spiked plasma. High levels of fibrinogen did not alter the assay or the effectiveness of heparins as measured in this assay. t-PA ROTEM was effective in measurement of both high fibrinogen and heparins spiked samples and was sensitive to the expected relevant coagulant changes by these conditions. No clear fibrinolytic effect was observed in different conditions.
This is an open access article under the terms of the Creative Commons Attribution-NonCommercial-NoDerivs License, which permits use and distribution in any medium, provided the original work is properly cited, the use is non-commercial and no modifications or adaptations are made.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.