BackgroundAn overall response assay [OVA, based on a 23-valent pneumococcal polysaccharide vaccine (PPV23)] is widely used to screen for anti-pneumococcal antibodies. Given the heterogeneity of response from one polysaccharide (PS) to another, a World Health Organization-standardized serotype-specific enzyme-linked immunosorbent assay (SSA) is considered to be the only reliable method for testing anti-PS antibody responses in individuals with suspected primary immunodeficiencies (PIDs).ObjectiveTo evaluate the OVA relative to the reference SSA.MethodsSerum samples of adult patients referred for a suspected PID were collected before and then 4–8 weeks after immunization with PPV23. The anti-pneumococcal response was systematically assessed with an SSA (7–16 serotypes) and interpreted according to the American Academy of Asthma, Allergy and Immunology’s current guidelines. We used receiver operating characteristic curves and agreement indices to assess the OVA’s diagnostic value in a first cohort. In order to validate these findings, a second (validation) cohort was then prospectively included.ResultsSixty-two adult patients were included, and 42 (67.7%) were defined as poor responders according to the SSA. Only the post-immunization titer in the OVA was able to correctly identify poor responders; a titer below 110 mg/L gave a positive predictive value of 100% [identifying 24 (57.1%) of the 42 poor responders], and similar levels of diagnostic performance were observed in the validation cohort. The pre-vaccination antibody titer, the post/pre-vaccination antibody titer ratio and a post-vaccination titer above 110 mg/L in the OVA were not predictive of the response in the SSA.ConclusionA post-vaccination antibody titer below 110 mg/L in the OVA was constantly associated with a poor PPV23 response using the SSA. In all other cases, SSA is the only reliable method for assessing diagnostic vaccination with PPV23.
Microsporidia are protists close to the kingdom of fungi that may cause eye infections. Most cases are reported in Asia and affect both immunocompromised and immunocompetent patients. Here, we report a rare case of microsporidial keratoconjunctivitis in an immunocompetent French patient 3 weeks after returning from India. In our patient, Weber trichrome staining of conjunctival scrapings revealed rounded elements approximately 1-3 μm in size. Conventional polymerase chain reaction analysis by ribosomal RNA subunit sequencing showed 100% identity with . Treatment by corneal debridement combined with fluoroquinolone eye drops allowed complete resolution of the lesions. Although rare, ocular microsporidiosis should be investigated in a patient who is native to Asia or has returned from an endemic area and presents with keratoconjunctivitis of undetermined etiology.
Our present results provide a reliable basis for the diagnosis of PIDs in childhood and for the accreditation of laboratories using Optilite® immunoturbidimetric reagents for IgG subclass measurement. Laboratory scientists and clinicians should be aware of the need for manufacturer-specific IgG subclass reference intervals.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.