Reliable detection of anticoagulation status in patients treated with non-vitamin K antagonist oral anticoagulants (NOACs) is challenging but of importance especially in the emergency setting. This study evaluated the potential of a whole-blood clotting time assay based on Surface Acoustic Waves (SAW-CT) in stroke-patients. The SAW-technology was used for quick and homogenous recalcification of whole blood inducing a surface-activated clotting reaction quantified and visualised by real-time fluorescence microscopy with automatic imaging processing. In 20 stroke or transient ischaemic attack (TIA)-patients taking NOACs kinetics of SAW-CT were assessed and correlated to other coagulation parameters (PT, aPTT) and NOAC-plasma concentration measured by tandem mass spectrometry (LC-MS/MS). In 225 emergency patients with suspicion of acute stroke or TIA, SAW-CT values were assessed. Mean (± SD) SAW-CT in non-anticoagulated stroke patients (n=180) was 124 s (± 21). In patients on dabigatran or rivaroxaban, SAW-CT values were significantly higher 2 and 8 hours (h) after intake rising up to 267 seconds (s) (dabigatran, 2 h after intake) and 250 s (rivaroxaban, 8 h after intake). In patients on apixaban, SAW-CT values were only moderately increased 2 h after intake (SAW-CT 153 s). In emergency patients, SAW-CT values were significantly higher in NOAC and vitamin K antagonist (VKA)-treated as compared to non-anticoagulated patients. In conclusion, the SAW-CT assay is capable to monitor anticoagulant level and effect in patients receiving dabigatran, rivaroxaban and the VKA phenprocoumon. It has a limited sensitivity for apixaban-detection. If specific SAW-CT results were used as cut-offs, SAW-CT yields high diagnostic accuracy to exclude relevant rivaroxaban and dabigatran concentrations in stroke-patients.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2025 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.