32 patients received a Trilogy- or Trilogy-Longevity-constrained acetabular liner for recurrent dislocations after total hip replacement. The constrained liner was inserted into a well-fixed Trilogy acetabular shell with snap fit. At 1.8-year followup (range 3–63 months), 4 patients had suffered further dislocation(s) (12%), and one patient had revision surgery for a loosened acetabular shell. Radiologic evaluation detected no definitively loose components, but one patient with progressing radiolucent lines around the femoral component and one patient with an acetabular cyst were found, as well as a patient with a loose locking ring (but otherwise no failure). The nineteen patients who were available for the present followup had a mean Harris Hip Score of 81. The constrained liner is an effective method of dealing with recurrent dislocations in well-fixed components.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.