<p>In 3D freehand ultrasound imaging, operator dependent variations in applied forces and movements can lead to errors in the reconstructed images. In this paper, we introduce an automated 3D ultrasound system, which enables acquisitions with controlled movement trajectories by using motors, which electrically move the probe. Due to integrated encoders there is no need of position sensors. An included force control mechanism ensures a constant contact force to the skin. We conducted 8 trials with the automated 3D ultrasound system on 2 different phantoms with 3 force settings and 10 trials on a human tibialis anterior muscle with 2 force settings. For comparison, we also conducted 8 freehand 3D ultrasound scans from 2 operators (4 force settings) on one phantom and 10 with one operator on the tibialis anterior muscle. Both freehand and automated trials showed small errors in volume and length computations of the reconstructions, however the freehand trials showed larger standard deviations. We also computed the thickness of the phantom and the tibialis anterior muscle. We found significant differences in force settings for the operators and higher coefficients of variation for the freehand trials. Overall, the automated 3D ultrasound system shows a high accuracy in reconstruction. Due to the smaller coefficients of variation, the automated 3D ultrasound system enables more reproducible ultrasound examinations than the freehand scanning. Therefore, the automated 3D ultrasound system is a reliable tool for 3D investigations of skeletal muscle.</p>
Skeletal muscle volume has been mainly investigated under static conditions, i.e. isometric contractions. The aim of our study is to use ultrasound imaging to determine muscle deformation during movement. We used a customdesigned scanning rig to obtain 3D ultrasound images of a subject moving the foot from plantarflexion to dorsiflexion at constant velocity. Using motion capture, we computed the respective angle of the ankle for each frame and collected them in bins based on the measured angle (rounded on the next normal number). For each degree, we used Stradwin for the 3D reconstruction of the respective volume. We found increasing cross-sectional areas for increasing dorsiflexion angles. The proposed method is a promising approach for determining muscle volume during movement. Future studies aim at collecting more data to compute muscle volume and length during contraction and compare the results to isometric measurements.
<p>In 3D freehand ultrasound imaging, operator dependent variations in applied forces and movements can lead to errors in the reconstructed images. In this paper, we introduce an automated 3D ultrasound system, which enables acquisitions with controlled movement trajectories by using motors, which electrically move the probe. Due to integrated encoders there is no need of position sensors. An included force control mechanism ensures a constant contact force to the skin. We conducted 8 trials with the automated 3D ultrasound system on 2 different phantoms with 3 force settings and 10 trials on a human tibialis anterior muscle with 2 force settings. For comparison, we also conducted 8 freehand 3D ultrasound scans from 2 operators (4 force settings) on one phantom and 10 with one operator on the tibialis anterior muscle. Both freehand and automated trials showed small errors in volume and length computations of the reconstructions, however the freehand trials showed larger standard deviations. We also computed the thickness of the phantom and the tibialis anterior muscle. We found significant differences in force settings for the operators and higher coefficients of variation for the freehand trials. Overall, the automated 3D ultrasound system shows a high accuracy in reconstruction. Due to the smaller coefficients of variation, the automated 3D ultrasound system enables more reproducible ultrasound examinations than the freehand scanning. Therefore, the automated 3D ultrasound system is a reliable tool for 3D investigations of skeletal muscle.</p>
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.