Escherichia coli O157:H7 fecal shedding in feedlot cattle is common and is a public health concern due to the risk of foodborne transmission that can result in severe, or even fatal, disease in people. Despite a large body of research, few practical and cost-effective farm-level interventions have been identified. In this study, a randomized controlled trial was conducted to assess the effect of reducing the level of water in automatically refilling water-troughs on fecal shedding of E. coli O157:H7 in feedlot cattle. Pens in a feedlot in the Texas Panhandle were randomly allocated as control (total number: 17) or intervention (total number: 18) pens. Fecal samples (2,759 in total) were collected both at baseline and three weeks after the intervention, and tested for the presence of E. coli O157:H7 using immunomagnetic bead separation and selective culture. There was a strong statistical association between sampling date and the likelihood of a fecal sample testing positive for E. coli O157:H7. Pen was also a strong predictor of fecal prevalence. Despite accounting for this high level of clustering, a statistically significant association between reduced water levels in the trough and increased prevalence of E. coli O157:H7 in the feces was observed (Odds Ratio = 1.6; 95% Confidence Interval: 1.2–2.0; Likelihood Ratio Test: p = 0.02). This is the first time that such an association has been reported, and suggests that increasing water-trough levels may be effective in reducing shedding of E. coli O157:H7 in cattle feces, although further work would be needed to test this hypothesis. Controlling E. coli O157:H7 fecal shedding at the pre-harvest level may lead to a reduced burden of human foodborne illness attributed to this pathogen in beef.
Background:The IDEXX SediVue Dx (SediVue) is an automated, in-clinic urine sediment analyzer for veterinary patients. The bias between the results from manual microscopy and the SediVue is currently unknown.Objectives: To assess the diagnostic accuracy of the SediVue, we aimed to determine the bias between the SediVue (index test) and manual microscopy (reference standard) for the quantification of RBCs and WBCs in urine.Methods: Urine remnant samples were collected from cats and dogs that contained RBCs (n = 462) and WBCs (n = 510). Retrospective analysis of results from urine sediment examinations using both manual microscopy (using a KOVA and DeciSlide system) and the SediVue (1.0.1.3) was performed. Bias was determined with Bland-Altman plots. SediVue-captured images from high-bias samples were reviewed, and biases were compared. Results:The median bias for semi-quantitative RBC and WBC counts was determined for RBC and WBC counts. The cutoffs were RBC ≤ 5/HPF, 0.3; RBC 5.1-10/HPF, 10.1;
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.