Oxinium is an alternative bearing surface designed to emulate the superior wear and scratch properties of ceramic femoral heads in total hip arthroplasty while minimizing the risk for brittle fracturing. However, recent studies have indicated that hip dislocation following total hip arthroplasty may be a risk factor for catastrophic failure of the femoral head. Here, we report on a novel case of a catastrophic Oxinium head and polyethylene liner failure in the absence of previous hip dislocation or trauma and review the probable failure mechanism. This report underscores the need to be vigilant about proper acetabular cup and liner seating, particularly in the setting of Oxinium femoral head use. In the event of Oxinium head failure, metallosis may compromise stabilizing soft tissues including the abductors. Dual-mobility articulation, which was successful in this case, is one option to consider when the risk for chronic redislocation is elevated.
Oxidized zirconium (OxZr) femoral heads were developed to emulate the superior wear and scratch properties of ceramics while eliminating their unwanted tendency for brittle fracturing. Studies using OxZr have demonstrated reduced linear and volumetric wear of polyethylene (PE) liners when compared with cobalt chrome, ceramic, and steel femoral heads. The purpose of this systematic review was to determine the difference in revision rates, radiologically determined linear wear rates, and patient-reported outcomes among OxZr and alternative bearing materials. Following the Preferred Reporting Items for Systematic Review and Meta-Analysis protocols, a systematic review of published literature through April 24, 2018 was conducted. Among the 862 cases included at a mean weighted follow-up of 4.78 years, the revision THA rate and patient-reported outcomes were similar among OxZr and alternative bearing materials. One of the five studies demonstrated significantly lower linear wear rates in the OxZr group when paired with ultrahigh molecular-weight PE (OxZr 0.03 mm/y vs. stainless-steel 0.11 mm/y; p < 0.001) and when paired with highly-crosslinked PE (OxZr 0.02 mm/y vs. stainless-steel 0.04 mm/y; p < 0.001). The remaining four studies found no difference in linear wear rates. OxZr demonstrated similar outcome to that of modern-day ceramic and metal femoral heads for short- and mid-term revision surgery rates and patient-reported outcomes. Longer term studies are needed to evaluate if any long-term wear advantages are seen with the use of OxZr femoral heads and if the use of OxZr is cost effective compared with ceramic or metal alternatives. The level of evidence of the study is level II, systematic review.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.