Lower-extremity wounds with exposed tendon, bone, or orthopedic hardware present a difficult treatment challenge. In this series of patients, subatmospheric pressure therapy was applied to such lower-extremity wounds. Seventy-five patients with lower-extremity wounds, most of which were the result of trauma, were selected for this study. Dressings made of sterile open-cell foam with embedded fenestrated tubing were contoured to the wound size and placed into the wound. The site was covered with an adhesive plastic sheet. The sheet was placed beneath any external fixation devices, or the fixation device was enclosed within the sheet. The tubing was connected to the vacuum-assisted closure pump. Continuous subatmospheric suction pressure (125 mmHg) was applied to the wound site. The wounds were inspected and the dressings were changed every 48 hours.Vacuum-assisted closure therapy greatly reduced the amount of tissue edema, diminishing the circumference of the extremity and thus decreasing the surface area of the wound. Profuse granulation tissue formed rapidly, covering bone and hardware. The wounds were closed primarily and covered with split-thickness skin grafts, or a regional flap was rotated into the granulating bed to fill the defect. Successful coverage was obtained without complication in 71 of 75 patients. Wounds have been stable from 6 months up to 6 years.
Treatment of wounds has been the cornerstone of plastic surgery since its inception. Vacuum-assisted closure provides a new paradigm that can be used in concert with a wide variety of standard existing plastic surgery techniques. It was originally developed as an alternative treatment for debilitated patients with chronic wounds. It has rapidly evolved into a widely accepted treatment of chronic and acute wounds, contaminated wounds, burns, envenomations, infiltrations, and wound complications from failed operations. The ease of technique and a high rate of success have encouraged its adaptation by thoracic, general, trauma, burn, orthopedic, urologic, as well as plastic surgeons. This article discusses multidisciplinary advances in the use of the vacuum-assisted closure technique over the past 10 years and its status as of 2006. Creative surgeons continue to regularly adapt the system to difficult problems. This technique in trained surgical hands greatly enhances the scope and safety of wound treatment.
In an effort to accelerate vascularization and simplify the care of Integra (Ethicon, Inc., Somerville, N.J.), topical subatmospheric pressure was used for eight patients (age range, 2 to 60 years) with complex wounds. Bone was exposed in 62.5 percent of cases, joint in 50 percent, tendon in 37.5 percent, and bowel in 25 percent. The estimated Integra take rate was 96 percent. Split-thickness skin grafting was performed at 4 to 11 days (mean, 7.25 days), with a 93 percent take rate. No adverse side effects were observed with this technique. Application of subatmospheric pressure improved the take rate and time to vascularization of Integra, compared with previous published results, even with complicated wounds. This technique may be a practical alternative to flap closure.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.