Category: Ankle Introduction/Purpose: Total ankle arthroplasty (TAA) is the alternative to tibio-talar fusion in the non-conservative operative treatment of osteoarthritis. It preserves joint range of motion and prevents adjacent joints while improving quality of life and relief. Long-term studies frequently show the presence of periprosthetic cysts, which is linked to an increased risk of revision, pain or lameness. In 2012, a stainless steel, DLC coated, TAA was subjected to a clinical review and a CT scan analysis. The main objective of this study was to analyze periprosthetic cysts evolution (numbers and volumes) on helical CT scans at 4 years apart of this same cohort of patients. The secondary objective was to present clinical results and survival curve of the implant. Methods: We retrospectively reviewed the cohort of 68 cases from 2012. The average follow-up was 13 ± 6 years. 42 CT analysis of the Periprosthetic cysts, were performed at the last follow-up and compared to the 2012 analysis. Cysts were classified in 3 groups (A: 0-200mm2, B: 200-400mm2, C:> 400 mm2) distributed over 7 areas. Numbers, locations and sizes were listed. The functional evaluation was performed in 2012 and at the last follow-up with the American Orthopedic Foot and Ankle Society Ankle and Hindfoot Score (AOFAS-AHS) and with the range of motion. TAR survival at 5 years were calculated for the 68 patients, and for the last 34 to avoid the learning curve effect. Two end points were defined: revision or removal of the implant for any reasons and revision or removal of the implant for aseptic loosening. TAR survival at 10 years was also analyzed thanks to the long follow-up. Results: Cysts size and prevalence were not significantly different at 4-year apart (p> 0.05). No type C cysts were revealed. The mean AOFAS-AHS was 77.6 ± 15.4 [38-98] in 2012 and stable at 75 ± 18.2 [16-97] at the last follow-up. Pre-operative ankle range of motion and at the last follow-up were not significantly different. The 5-year survival for the last 34 cases were 85.2% [73.2; 97.2] for any cause of revision and 90.7% [80.7; 100] for aseptic loosening. The 10-year survival for the last 34 cases were 77.1% [67.3; 87.4] for any cause of revision and 85.4% [73.4; 98.4] for aseptic loosening. Between 2012 and 2016, one case was revised for aseptic loosening of the talar component and two cases needed fusion. Conclusion: This study shows no significant increase of cysts volume or number at 4-year apart with a stainless steel, DLC coated TAA. The clinical results and 5-year survival are similar to those in the literature. The strength of this study is its mean follow-up greater than 13 years which allowed a 10-year survival and a long-term CT scan analysis. The implant design (spherical tibial component, dual curvature PE insert, trochlear-shaped talar component), its materials (DLC coated stainless steel) and its fixation (alumina coating) ensure long-term similar clinical results, with no break after 5-year survival, and stability of cysts prevalence ...
Introduction/Purpose: In 2010, a new closed reduction, internal fixation procedure for displaced intra-articular calcaneus fractures (DIACF) was developed with an intramedullary nail introduces through a channel in the calcaneal tuberosity. The goal was to reduce the rate of skin complications following principles of open reduction procedures. The aim of this prospective mono-centric study was to assess the occurrence of complications and the functional results using the AOFAS-AHS score. The secondary objectives were to assess first the restoration of the Böhler and Gissane angles on X-ray and shape of the calcaneus (Height, length, width) on CT scans, then thalamic reduction on 3D CT scans based on Goldzak's global articular reduction classification.Methods: 26 Patients were included prospectively between 2014 and 2016 with analysis of X-rays and CT scans. Two were lost to follow-up and 2 patients sustained a secondary subtalar arthrodesis. After positioning a distractor and drilling, reduction was done with tamps and spatula. The nail was then introduced and locked with screws in the tuberosity and the constant fragment. After 3 weeks of non-weight bearing and 3 weeks with hindfoot off-loading shoe, full weight bearing was allowed. The functional outcome and restoration of the radiographic angles were evaluated postoperatively, at 3 months, 1 year and at the last follow-up. Global calcaneal shape and thalamic surface were evaluated postoperatively, at 1 year and at the last follow-up. The following early complications (delayed healing, infection, annoyed material, sural nerve lesion) and later complications (painful stiffness of the subtalar joint, hindfoot varus malalignment and calcaneofibular conflict) were recorded.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2025 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.