Background-Arrhythmogenic right ventricular cardiomyopathy/dysplasia (ARVC/D) is a condition associated with the risk of sudden death (SD). Methods and Results-We conducted a multicenter study of the impact of the implantable cardioverter-defibrillator (ICD) for prevention of SD in 132 patients (93 males and 39 females, age 40Ϯ15 years) with ARVC/D. Implant indications were a history of cardiac arrest in 13 patients (10%), sustained ventricular tachycardia in 82 (62%), syncope in 21 (16%), and other in 16 (12%). During a mean follow-up of 39Ϯ25 months, 64 patients (48%) had appropriate ICD interventions, 21 (16%) had inappropriate interventions, and 19 (14%) had ICD-related complications. Fifty-three (83%) of the 64 patients with appropriate interventions received antiarrhythmic drug therapy at the time of first ICD discharge. Programmed ventricular stimulation was of limited value in identifying patients at risk of tachyarrhythmias during the follow-up (positive predictive value 49%, negative predictive value 54%). Four patients (3%) died, and 32 (24%) experienced ventricular fibrillation/flutter that in all likelihood would have been fatal in the absence of the device. At 36 months, the actual patient survival rate was 96% compared with the ventricular fibrillation/flutter-free survival rate of 72% (PϽ0.001). Patients who received implants because of ventricular tachycardia without hemodynamic compromise had a significantly lower incidence of ventricular fibrillation/flutter (log rankϭ0.01). History of cardiac arrest or ventricular tachycardia with hemodynamic compromise, younger age, and left ventricular involvement were independent predictors of ventricular fibrillation/flutter. Conclusions-In
Different methods for venous access are used for permanent pacemaker or implantable cardioverter defibrillator (ICD), of which subclavian vein puncture technique is the most widely practised. Although this approach is relatively easy to learn, quick and offers high success rates, it may be associated with potential serious acute complications including pneumothorax, emopneumothorax, brachial plexus injury and longer-term complications such as lead fracture, loss of lead insulation and subclavian crush syndrome especially in young patients with ICD leads. Axillary vein approach seems to be a favourable technique not only for the prevention of acute complications but also to reduce lead failure including lead insulation and lead fracture prevention with a consequently better long-term lead survival compared with the classical subclavian approach. Although randomized studies are lacking, recent reports not only evaluated the safety and effectiveness of new fluoroscopic axillary venous puncture technique, but also compared it with the conventional intrathoracic subclavian venous puncture technique for the implantation of leads in permanent pacing. Various techniques of axillary vein puncture have been proposed ranging from a blind percutaneous puncture to the use of different tools such as contrast venography and ultrasound. In this article, we report a case of subclavian crush syndrome, the use of a modified Bellot's technique of axillary vein puncture that we currently use and the potential benefits of axillary vein puncture for pacemaker and ICD leads implantation compared with subclavian approach to avoid acute and long-term lead complications.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.