Objective: The virtual cone beam computed tomography–derived 3-dimensional model was compared with the scanned conventional model used in the fabrication of a palatal obturator for a patient with a large palatal defect. Design: A digitally derived 3-dimensional maxillary model incorporating the palatal defect was generated from the patient’s existing cone beam computerized tomography data and compared with the scanned cast from the conventional impression for linear dimensions, area, and volume. The digitally derived cast was 3-dimensionally printed and the obturator fabricated using traditional techniques. Similarly, an obturator was fabricated from the conventional cast and the fit of both final obturator bulbs were compared in vivo. Results: The digitally derived model produced more accurate volumes and surface areas within the defect. The defect margins and peripheries were overestimated which was reflected clinically. Conclusion: The digitally derived model provided advantages in the fabrication of the palatal obturator; however, further clinical research is required to refine consistency.
Purpose Mesh optimization reduces the texture quality of 3D models in order to reduce storage file size and computational load on a personal computer. This study aims to explore mesh optimization using open source (free) software in the context of prosthodontic application. Materials and Methods An auricular prosthesis, a complete denture, and anterior and posterior crowns were constructed using conventional methods and laser scanned to create computerized 3D meshes. The meshes were optimized independently by four computer‐aided design software (Meshmixer, Meshlab, Blender, and SculptGL) to 100%, 90%, 75%, 50%, and 25% levels of original file size. Upon optimization, the following parameters were virtually evaluated and compared; mesh vertices, file size, mesh surface area (SA), mesh volume (V), interpoint discrepancies (geometric similarity based on virtual point overlapping), and spatial similarity (volumetric similarity based on shape overlapping). The influence of software and optimization on surface area and volume of each prosthesis was evaluated independently using multiple linear regression. Results There were clear observable differences in vertices, file size, surface area, and volume. The choice of software significantly influenced the overall virtual parameters of auricular prosthesis [SA: F(4,15) = 12.93, R2 = 0.67, p < 0.001. V: F(4,15) = 9.33, R2 = 0.64, p < 0.001] and complete denture [SA: F(4,15) = 10.81, R2 = 0.67, p < 0.001. V: F(4,15) = 3.50, R2 = 0.34, p = 0.030] across optimization levels. Interpoint discrepancies were however limited to <0.1mm and volumetric similarity was >97%. Conclusion Open‐source mesh optimization of smaller dental prostheses in this study produced minimal loss of geometric and volumetric details. SculptGL models were most influenced by the amount of optimization performed.
Purpose: This systematic review and meta-analysis explored the factors involved in the color stability and degradation of Maxillo-Facial Prosthetic Silicone Elastomer (MFPSE). Further exploration was done to analyze past literature discussing the potential benefits to color stability when nano-particles were combined with pigmented MFPSE. Method: The search for the articles was done according to PRISMA guidelines. Articles were searched from “Scopus” and “Web of Sciences” from the year 1970 to 2019. Searches were carried out by two reviewers until November 2019. Articles for systematic review were selected based on predefined eligibility criteria. Information regarding weathering conditions, pigments and filler-particle inclusion were extracted as appropriate. Further screening was done for meta-analyze case-control studies of red, blue and yellow pigments according to predefined scoring criteria. Meta-analysis was conducted on case-control studies that incorporated 5%,10% and 15% TiO2 in MFPSE with the said pigments and was carried out using Cochrane Review Manager 5.3. Results: 30 studies were selected for systematic review and 6 studies were eligible for meta-analysis. The most prominent influencers of color stability were nano-fillers and the type of color used in the mixing. Furthermore, experimental conditions, weathering, color of investment plaster and the method of color detection all affected the degree of degradation. There was an overall significant difference found when TiO2 was incorporated with the pigmented silicone. There is significant difference when 10% ( P = 0.0004) TiO2 is incorporated with the red pigment, 5% ( P = 0.03) TiO2 with the yellow and 10% ( P < 0.0001) and 15% ( P = 0.02) TiO2 with the blue pigment. Conclusion: Type of pigment and nano-filler incorporated into the silicone play a role in influencing color stability. Incorporation of 10% TiO2 with red pigment,5% with yellow pigment and 10% or 15% TiO2 with blue pigment provided some protection to the silicone elastomer from color degradation.
Background The study aimed to evaluate 1) the amount of color variations presents within clinical images of maxillofacial prosthetic silicone specimens when photographed under different clinically relevant ambient lighting conditions, and 2) whether white balance calibration (WBC) methods were able to mitigate variations in ambient lighting. Methods 432 measurements were acquired from standardized images of the pigmented prosthetic silicone specimens within different ambient lighting conditions (i.e., 2 windowed and 2 windowless clinics) at noon with no light modifying apparatus. The specimens were photographed once without any white balance calibration (raw), then independently alongside an 18% neutral gray card and Macbeth color chart for calibration in a post-processing (PPWBC) software, and once after camera calibration (CWBC) using a gray card. The LAB color values were extracted from the images and color variations (ΔE) were calculated after referring to the corresponding spectrophotometric values as control. Results Images in windowless and windowed clinics exhibited highly significant differences (p < 0.001) with spectrophotometer (control). CWBC demonstrated no significant differences (p > 0.05) in LAB values across windowed clinics. PPWBC using Macbeth color chart produced no significant differences for a* values (p > 0.05) across all clinics while PPWBC by gray card showed no significant differences (p > 0.05) in LAB values when only similar clinics (either windowed or windowless) were compared. Conclusion Significant color variations were present for maxillofacial prosthetic specimens owing to natural ambient light. CWBC and PPWBC using color charts were more suitable for color correction across windowed clinics while CWBC and PPWBC using gray cards had better outcomes across windowless setups.
Although numerous studies have demonstrated the benefits of incorporating filler particles into maxillofacial silicone elastomer (MFPSE), a review of the types, concentrations and effectiveness of the particles themselves was lacking. The purpose of this systematic review and meta-analysis was to review the effect of different types of filler particles on the mechanical properties of MFPSE. The properties in question were (1) tensile strength, (2) tear strength, (3) hardness, and (4) elongation at break. The findings of this study can assist operators, technicians and clinicians in making relevant decisions regarding which type of fillers to incorporate based on their needs. The systematic review was performed according to Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) guidelines. A total of 26 original articles from 1970 to 2019 were selected from the databases, based on predefined eligibility criteria by two reviewers. The meta-analyses of nine papers were carried out by extracting data from the systematic review based on scoring criteria and processed using Cochrane Review Manager 5.3. Overall, there were significant differences favoring filler particles when incorporated into MFPSE. Nano fillers (69.23% of all studies) demonstrated superior comparative outcomes for tensile strength (P < 0.0001), tear strength (P < 0.00001), hardness (P < 0.00001) and elongation at break (P < 0.00001) when compared to micro fillers (30.76% of all studies). Micro fillers demonstrated inconsistent outcomes in mechanical properties, and meta-analysis of elongation at break argued against (P < 0.01) their use. Current findings suggest that 1.5% ZrSiO4, 3% SiO2, 1.5% Y2O3, 2–6% TiO2, 2–2.5% ZnO, 2–2.5% CeO2, 0.5% TiSiO4 and 1% Ag-Zn Zeolite can be used to reinforce MFPSE, and help the materials better withstand mechanical degradation.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.