Background: Permanent right ventricular apical pacing may have negative effects on ventricular function and contribute to development of heart failure. We aimed to assess intra- and interventricular mechanical dyssynchrony in patients with permanent right ventricular apical pacing, and to establish electrocardiographic markers of dyssynchrony. Methods: 84 patients (46:38 male:female) who required permanent pacing were studied. Pacing was done from right ventricular apex in all patients. We measured QRS duration and dispersion on standard 12-lead ECG. Intra- and interventricular mechanical dyssynchrony and left ventricular ejection fraction were assessed by transthoracic echocardiography. Patients were followed-up for 24 months. Results: Six months after implantation, QRS duration increased from 128.02 ms to 132.40 ms, p≤0.05. At 24 months, QRS dispersion increased from 43.26 ms to 46.13 ms, p≤0.05. Intra- and interventricular dyssynchrony increased and left ventricular ejection fraction decreased during follow-up. A QRS dispersion of 47 ms predicted left ventricular dysfunction and long-term electromechanical dyssynchrony with a sensitivity of 80% and a specificity of 76%. Conclusion: In patients with permanent right ventricular apical pacing there is an increased duration and dispersion of QRS related to dyssynchrony and decreased left ventricular ejection fraction. This study shows that QRS dispersion could be a better predictive variable than QRS duration for identifying left ventricular ejection fraction worsening in patients with permanent right ventricular apical pacing. The electrocardiogram is a simple tool for predicting systolic function worsening in these patients and can be used at the bedside for early diagnosis in the absence of clinical symptoms, allowing adjustments of medical treatment to prevent progression of heart failure and improve the patient's quality of life.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2025 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.