where the flow reversal normally starts at 86% -chord. A total drag increase of 22% is detected because of the sharp leading-edge of the device, but the main element drag has a reduction of 43%.The maximum lift coefficient does not show a significant change on the same model. The second device (Cylinder) has a negative effect, initiating flow separation and causing a significant decrease in lift-to-drag ratio at a given lift coefficient. The third device (Dimples) demonstrates the potential of lift-to-drag ratio improvement at the higher angle-of-attack. Further investigation is required to verify the results since the improvement is small.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.