The new transcutaneous bone conduction implant was demonstrated to be safe and effective in adults up to 3 months of device use.
The objective of this study was to investigate the occurrence of vestibular receptor deficiency and taste disorders after bilateral cochlear implantation in postlingually deafened patients and to find out whether the risk for these complications is higher for the second implantation. In a retrospective cohort study, we examined 20 patients (11-58 years, mean age 41.5 years), implanted sequentially between 2000 and 2007 (mean period between cochlear implantation 32.9 ± 25 months). Pre- and postoperative vestibular testing was performed by subjective rating [Dizziness Handicap Inventory (DHI)], caloric irrigation [vestibuloocular reflex (VOR)] and by vestibular-evoked myogenic potential (VEMP) recordings for saccular function. The sense of taste was evaluated pre- and postoperatively by a questionnaire and testing (sour/sweet/bitter/salty bilaterally on the tongue). DHI evaluation showed a moderate not significant mean increase by 2.7 ± 7.7 SD points after the first and a significant increase by 9.4 ± 16.6 SD points after the second implantation. Ipsilateral VEMP responses disappeared in three ears (27.3%) after the first and in two ears (18.2%) after the second operation. VOR disappeared only once (5.9%) after the first implantation. One (5%) patient complained of a persisting disturbance of taste in the questionnaire after unilateral and 3 (15%) after bilateral implantation. Specific testing showed in one case (5%) a unilateral taste disorder after ipsilateral cochlear implantation. Our data show that there is a higher risk for subjective vertigo after the second implantation. The occurrence of unilateral and/or bilateral vestibular dysfunction and the potential risk of taste disorder should be included in the risk counseling before bilateral cochlear implantation to increase patients' and medicolegal safety in the decision-making process.
The evaluation of specific intraoperative electrophysiologic data allowed separating between a regular and an irregular (i.e., scalar changing) position of CI electrodes. This noninvasive methodology can support the postoperative radiologic evaluation of the CI electrode array position.
Objective: To evaluate the long-term safety and performance of four different vibroplasty couplers (round window, oval window, CliP and Bell coupler) in combination with an active middle ear implant. Methods: This was a multicentre, prospective, long-term study including 5 German hospitals. Thirty adult subjects suffering from conductive or mixed hearing loss were initially enrolled for the study, 24 of these were included in the final analysis with up to 36 months of postsurgical follow-up data. Bone conduction and air conduction were measured pre- and postoperatively to evalu ate safety. Postoperative aided sound field thresholds and Freiburger monosyllable word recognition scores were compared to unaided pre-implantation results to confirm performance. Additional speech tests compared postoperative unaided with aided results. To determine patient satisfaction, an established quality-of-life questionnaire developed for conventional hearing aid usage was administered to all subjects. Results: Mean postoperative bone conduction thresholds remained stable throughout the whole study period. Mean functional gain for all couplers investigated was 38.5 ± 11.4 dB HL (12 months) and 38.8 ± 12.5 dB HL (36 months). Mean word recognition scores at 65 dB SPL increased from 2.9% in the unaided by 64.2% to 67.1% in the aided situation. The mean postoperative speech reception in quiet (or 50% understanding of words in sentences) shows a speech intelligibility improvement at 36 months of 17.8 ± 12.4 dB SPL over the unaided condition. The signal-to-noise ratio (SNR) improved by 5.9 ± 7.2 dB SNR over the unaided condition. High subjective device satisfaction was reflected by the International Inventory for Hearing Aids scored very positively. Conclusion: A significant improvement was seen with all couplers, and audiological performance did not significantly differ between 12 and 36 months after surgery.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.