Based on the noninvasive Vogele-Bale-Hohner vacuum mouthpiece, there is no need for invasive head clamp fixation. Imaging, real laboratory simulation, and the actual surgical intervention can be separated in time and location. The presented data suggest that frameless stereotaxy is a predictable and reproducible procedure, which may enhance patient security and cannulation success independent of the surgeon's experience.
Because we are performing TKAs on heavier, younger patients, greater stress is being put on the implants and is increasing the importance of implantation accuracy. We performed a prospective randomized study to compare the radiographic results and the 3-month clinical outcomes in 100 patients who had TKAs using an imageless navigation system with 100 patients treated using conventional implantation instruments. We measured component alignment by standard radiographs. Clinical outcomes were based on the Insall score, anterior knee pain, feeling of instability, and the step test. The mechanical axis of the limb was within 3 degrees varus/valgus in 92% of the patients who had navigated procedures versus 76% of patients who had conventional surgery. The tibial slope showed a rate of inaccuracy of 3 degrees or less for 98% of the patients in the navigated TKA group versus 80% of the patients in the conventional group. The surgical time was longer for navigated TKA than for the conventional procedure (88 +/- 16 versus 68 +/- 18 minutes, respectively). Clinical outcomes and postoperative blood loss were similar in both groups. The navigation system increased implantation accuracy but did not prevent outliers and did not solve the problems associated with identifying and obtaining accurate component rotation.
Frameless stereotactic procedures crucially depend on the firmness of immobilization. Once registered, shifting of the patient leads to inaccuracy, and the patient registration has to be realigned. To overcome the drawbacks of conventional invasive fixation for neurosurgery and the widely accepted fixation with surgical tape in ENT, the Vogele-Bale-Hohner (VBH) head holder has been developed. It permits rigid, noninvasive fixation of the head by using an individualized dental cast attached to the upper jaw by vacuum. Oral intubation is uncomplicated. In addition, a special registration device providing well defined reference points can be mounted to the mouthpiece. We report the first promising clinical applications of this device.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.