Background Serological testing based on different antibody types are an alternative method being used to diagnose SARS-CoV-2 and has the potential of having higher diagnostic accuracy compared to the current gold standard rRT-PCR. Therefore, the objective of this review was to evaluate the diagnostic accuracy of IgG and IgM based point-of-care (POC) lateral flow immunoassay (LFIA), chemiluminescence enzyme immunoassay (CLIA), fluorescence enzyme-linked immunoassay (FIA) and ELISA systems that detect SARS-CoV-2 antigens. Method A systematic literature search was carried out in PubMed, Medline complete and MedRxiv. Studies evaluating the diagnostic accuracy of serological assays for SARS-CoV-2 were eligible. Study selection and data-extraction were performed by two authors independently. QUADAS-2 checklist tool was used to assess the quality of the studies. The bivariate model and the hierarchical summary receiver operating characteristic curve model were performed to evaluate the diagnostic accuracy of the serological tests. Subgroup meta-analysis was performed to explore the heterogeneity. Results The pooled sensitivity for IgG (n = 17), IgM (n = 16) and IgG-IgM (n = 24) based LFIA tests were 0.5856, 0.4637 and 0.6886, respectively compared to rRT-PCR method. The pooled sensitivity for IgG (n = 9) and IgM (n = 10) based CLIA tests were 0.9311 and 0.8516, respectively compared to rRT-PCR. The pooled sensitivity the IgG (n = 10), IgM (n = 11) and IgG-IgM (n = 5) based ELISA tests were 0.8292, 0.8388 and 0.8531 respectively compared to rRT-PCR. All tests displayed high specificities ranging from 0.9693 to 0.9991. Amongst the evaluated tests, IgG based CLIA expressed the highest sensitivity signifying its accurate detection of the largest proportion of infections identified by rRT-PCR. ELISA and CLIA tests performed better in terms of sensitivity compared to LFIA. IgG based tests performed better compared to IgM except for the ELISA. Conclusions We report that IgG-IgM based ELISA tests have the best overall diagnostic test accuracy. Moreover, irrespective of the method, a combined IgG/IgM test seems to be a better choice in terms of sensitivity than measuring either antibody type independently. Given the poor performances of the current LFIA devices, there is a need for more research on the development of highly sensitivity and specific POC LFIA that are adequate for most individual patient applications and attractive for large sero-prevalence studies. Systematic review registration PROSPERO CRD42020179112
Background Schistosomiasis is a devastating parasitic disease. The mainstay of schistosomiasis control is by praziquantel treatment. The study aimed to determine benefits of annual chemotherapy of schistosomiasis on development of protective immunity in school children in a selected endemic rural area in Zimbabwe. Methods Urine specimens from 212 school children (7–13 years) were collected and examined to determine prevalence, intensity and reinfection of S.haematobium at baseline, 6 weeks and 2 years following annual rounds of praziquantel treatment . Blood samples from the participants were assayed for total and S. haematobium (Sh13)-specific antibodies before and 2 years after annual rounds of treatment. Results Annual treatment reduced the prevalence of S. haematobium infection ( p < 0.05) from 23.1% at baseline to 0.47% after 2 years. Overall cure rate was 97.8%. Intensity of infection declined (p < 0.05) from 15.9 eggs/10 ml urine at baseline to 2 eggs/10 ml urine. After two years, overall rate of reinfection was 0.96%. At baseline, total IgG4 was higher in S. haematobium -infected children ( p = 0.042) ,while all other immunoglobulins were within normal ranges. There was an increase in total IgG2 ( p = 0.044) levels and a decrease in total IgG4 ( p = 0.031) levels 2 years post-treatment; and no significant changes in other total immunoglobulins. Schistosoma -infected children at baseline showed an increase in anti- Sh 13 IgG1 ( p = 0.005) and a decrease in Sh 13 IgG4 levels ( p = 0.012) following treatment. Conclusion Annual praziquantel treatment delivered to school children over 2 years significantly reduce prevalence, intensity of infection and reinfection of S. haematobium infection. Treatment was also observed to cause a reduction in schistosome-specific blocking IgG4 and an increase in Schistosoma -specific protecting IgG1. Electronic supplementary material The online version of this article (10.1186/s12879-019-3811-z) contains supplementary material, which is available to authorized users.
Background: Serological testing based on different antibody types are an alternative method being used to diagnose SARS-CoV-2 and has the potential of having higher diagnostic accuracy compared to the current gold standard RT-PCR. Therefore, the objective of this review was to evaluate the diagnostic accuracy of IgG and IgM based Point-of-care (POC) lateral flow immunoassays (LFIA), chemiluminescence enzyme immunoassay (CLIA), fluorescence enzyme-linked immunoassay (FIA) and ELISA systems that detect SARS-CoV-2 antigens.Method: A systematic literature search was carried out in PubMed, Medline complete and MedRxiv. Studies evaluating the diagnostic accuracy of serological assays for SARS-CoV-2 were eligible. Study selection and data-extraction were done by two authors independently. QUADAS-2 checklist tool was used to assess the quality of the studies. The bivariate model and the hierarchical summary receiver operating characteristic curve model were performed to evaluate the diagnostic accuracy of the serological tests. Subgroup meta-analysis analyses was performed to explore the heterogeneity. Results: The pooled sensitivity for IgG, IgM and IgG-IgM based LFIA tests were 0.5856, 0.4637 and 0.6886 respectively compared to RT-PCR method. The pooled sensitivity for IgG and IgM based CLIA tests were 0.9311 and 0.8516 respectively compared to RT-PCR. The pooled sensitivity the IgG, IgM and IgG-IgM based ELISA tests were 0.8292, 0.8388 and 0.8531 respectively compared to RT-PCR. All tests displayed high specificities ranging from 0.9693 to 0.9991. Among the evaluated tests, IgG based CLIA expressed the highest sensitivity signifying its accurate detection of the largest proportion of infections identified by RT-PCR. ELISA and CLIA tests performed better in terms of sensitivity compared to LFIA. IgG based tests performed better compared to IgM ones expect for the ELISA. Conclusions: We report that IgG-IgM based ELISA tests have the best overall diagnostic test accuracy. Moreover, irrespective of the method, a combined IgG/IgM test seems to be a better choice in terms of sensitivity than measuring either antibody type independently. Given the poor performances of the current LFIA devices there is need for more research on the development of highly sensitivity and specific POC LFIA that are adequate for most individual patient applications and attractive for large sero-prevalence studies.Systematic review registration: PROSPERO Registration Number is: CRD42020179112
Introduction This scoping review explores the use of peptide microarrays in the fight against infectious diseases. The research domains explored included the use of peptide microarrays in the mapping of linear B-cell and T cell epitopes, antimicrobial peptide discovery, immunosignature characterisation and disease immunodiagnostics. This review also provides a short overview of peptide microarray synthesis. Methods Electronic databases were systematically searched to identify relevant studies. The review was conducted using the Joanna Briggs Institute methodology for scoping reviews and data charting was performed using a predefined form. The results were reported by narrative synthesis in line with the Preferred Reporting Items for Systematic reviews and Meta-Analyses extension for Scoping Reviews guidelines. Results Ninety-five articles from 103 studies were included in the final data charting process. The majority (92. 0%) of the articles were published during 2010–2020 and were mostly from Europe (44.2%) and North America (34.7%). The findings were from the investigation of viral (45.6%), bacterial (32. 0%), parasitic (23.3%) and fungal (2. 0%) infections. Out of the serological studies, IgG was the most reported antibody type followed by IgM. The largest portion of the studies (77.7%) were related to mapping B-cell linear epitopes, 5.8% were on diagnostics, 5.8% reported on immunosignature characterisation and 8.7% reported on viral and bacterial cell binding assays. Two studies reported on T-cell epitope profiling. Conclusion The most important application of peptide microarrays was found to be B-cell epitope mapping or antibody profiling to identify diagnostic and vaccine targets. Immunosignatures identified by random peptide microarrays were found to be applied in the diagnosis of infections and interrogation of vaccine responses. The analysis of the interactions of random peptide microarrays with bacterial and viral cells using binding assays enabled the identification of antimicrobial peptides. Peptide microarray arrays were also used for T-cell linear epitope mapping which may provide more information for the design of peptide-based vaccines and for the development of diagnostic reagents.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.