A b s t r a c tBackground: Structural heart disease, including valvular disease as well as congenital defects, causes important alterations in heart anatomy. As a result, individualised planning for both surgical and percutaneous procedures is crucial for procedural optimisation. Three dimensional (3D) rapid prototyping techniques are being utilised to aid operators in planning structural heart procedures. Aim:We intend to provide a description of 3D printing as a clinically applicable heart modelling technology for the planning of percutaneous structural heart procedures as well as to report our first clinical use of a 3D printed patient-specific heart model in preparation for a percutaneous mitral annuloplasty using the Mitralign percutaneous annuloplasty system. Methods:Retrospectively gated, contrast enhanced, multi-slice computed tomography (MSCT) scans were obtained. MSCT DICOM data was analysed using software that creates 3D surface files of the blood volume of specific regions of interest in the heart. The surface files are rendered using a software package that creates a solid model that can be printed using commercially available stereolithography machines. Results:The technique of direct percutaneous mitral annuloplasty requires advancement of a guiding catheter through the aorta, into the left ventricle, and requires the positioning of the tip of the catheter between the papillary muscles in close proximity to the mitral annulus. The 3D heart model was used to create a procedural plan to optimise potential device implantation. The size of the deflectable guiding catheter was selected on the basis of the patient's heart model. Target locations for annulus crossing wires were evaluated pre-procedurally using the individual patient's 3D heart model. In addition, the ability to position the Bident Catheter at the appropriate locations under the mitral annulus as well as the manoeuvrability between the papillary muscles were analysed on the heart model, enabling safe completion of the procedure, which resulted in a significant reduction in mitral regurgitation.Conclusions: 3D printing is a helpful tool in individualised planning for percutaneous structural interventions. Future studies are warranted to assess its role in preparing for percutaneous and surgical heart procedures.
Percutaneous mitral annuloplasty with the Mitralign Bident system is feasible. Future clinical trials are needed to assess its safety and efficacy.
ICD implantation is standard therapy for malignant ventricular arrhythmias. The advantage of dual and single coil defibrillator leads in the successful conversion of arrhythmias is unclear. This study compared the effectiveness of dual versus single coil defibrillation leads. The study was a prospective, multicenter, randomized study comparing a dual with a single coil defibrillation system as part of an ICD using an active pectoral electrode. Seventy-six patients (64 men, 12 women; age 61 +/- 11 years) were implanted with a dual (group 1, n = 38) or single coil lead system (group 2,n = 38). The patients represented a typical ICD cohort: 60% presented with ischemic cardiomyopathy as their primary cardiac disease, the mean left ventricular ejection fraction was 0.406 +/- 0.158. The primary tachyarrhythmia was monomorphic ventricular tachyarrhythmia in 52.6% patients and ventricular fibrillation in 38.4%. There was no significant difference in terms of P and R wave amplitudes, pacing thresholds, and lead impedance at implantation and follow-up in the two groups. There was similarly no difference in terms of defibrillation thresholds (DFT) at implantation. Patients in group 1 had an average DFT of 10.2 +/- 5.2 J compared to 10.3 +/- 4.1 J in Group 2, P = NS. This study demonstrates no significant advantage of a dual coil lead system over a single coil system in terms of lead values and defibrillation thresholds. This may have important bearing on the choice of lead systems when implanting ICDs.
Background: Atrial fibrillation (AF) is the most common cardiac arrhythmia. Thus, the aim of our study was to evaluate the smartphone-based electrocardiogram (ECG) recordings aimed at AF screening at Polish pharmacies. Methods: Prospective AF screening among patients aged ≥65 years was conducted at 10 pharmacies using Kardia Mobile with a dedicated application (Kardia app). Prior AF was a study exclusion criterion. CHA2DS2-VASc score (congestive heart failure, hypertension, age, diabetes mellitus, previous stroke/transient ischemic attack, female sex, and vascular disease) has been collected from every patient. A single-lead ECG has been acquired by the placement of fingers from each hand on the pads. Kardia app diagnosis has been evaluated by the cardiologist. Results: A total of 525 ECGs were performed. Kardia app diagnosis was provided in 490 cases. In 437 (89.18%) cases, it was “normal” rhythm, in 17 (3.47%) recordings “possible AF,” in 23 (4.69%) ECGs “unreadable,” and in 13 (2.65%) “unclassified”. After the cardiologist reevaluation, the new AF was identified in 7 (1.33%) patients. Sensitivity and specificity of Kardia app in detecting AF was 100% (95% confidence interval [CI]: 71.5%-100%) and 98.7% (95% CI: 97.3%-99.5%), respectively. The positive predictive value was 64.7% (95% CI: 38.3%-85.7%) and the negative predictive value was 100% (95% CI: 99.2%-100%). CHA2DS2-VASc score was 2.14 ± 0.69 for those with new AF and 3.33 ± 1.26 in the non-AF group. Conclusion: Kardia app is capable of fast screening and detecting AF with high sensitivity and specificity. The possible diagnosis of AF deserves additional cardiological evaluation. The results obtained in patients with low CHA2DS2-VASc score and “silent” AF confirm the importance of routine AF screening. Cardiovascular screening with the use of mobile health technology is feasible at pharmacies.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.