Background COVID-19 patients can develop a cytokine release syndrome that eventually leads to acute respiratory distress syndrome (ARDS) requiring invasive mechanical ventilation (IMV). Since interleukin-6 (IL-6) is a relevant cytokine in ARDS, the blockade of its receptor with Tocilizumab (TCZ) could reduce mortality and/or morbidity in severe COVID-19. Objective To determine whether baseline IL-6 serum levels can predict the need for IMV and the response to TCZ. Methods Retrospective observational study performed in hospitalized patients diagnosed of COVID-19. Clinical information and laboratory findings, including IL-6 levels, were collected approximately 3 and 9 days after admission to be matched with pre- and post-administration of TCZ. Multivariable logistic and linear regressions, and survival analysis were performed depending on outcomes: need for IMV, evolution of arterial oxygen tension/fraction of inspired oxygen ratio (PaO 2 /FiO 2 ) or mortality. Results One hundred and forty-six patients were studied, predominantly male (66%); median age was 63 years. Forty-four patients (30%) required IMV, and 58 patients (40%) received treatment with TCZ. IL-6 levels>30 pg/ml was the best predictor for IMV (OR:7.1; p<0.001). Early administration of TCZ was associated with improvement of oxygenation (PaO 2 /FiO 2 ) in patients with high IL-6 (p=0.048). Patients with high IL-6 not treated with TCZ showed high mortality (HR: 4.6; p=0.003), as well as those with low IL-6 treated with TCZ (HR: 3.6; p=0.016). No relevant serious adverse events were observed in TCZ-treated patients. Conclusion Baseline IL-6>30 pg/ml predicts IMV requirement in patients with COVID-19 and contributes to establish an adequate indication for TCZ administration.
Introduction: Severe Acute Respiratory Syndrome Coronavirus-2 (SARS-CoV-2) specific antibodies have been shown to neutralize the virus in-vitro. Understanding antibody dynamics following SARS-CoV-2 infection is therefore crucial. Sensitive measurement of SARS-CoV-2 antibodies is also vital for large seroprevalence surveys which inform government policies and public health interventions. However, rapidly waning antibodies following SARS-CoV-2 infection could jeopardize the sensitivity of serological testing on which these surveys depend. Methods: This prospective cohort study of SARS-CoV-2 humoral dynamics in a central London hospital analyzed 137 serial samples collected from 67 participants seropositive to SARS-CoV-2 by the Meso-Scale Discovery assay. Antibody titers were quantified to the SARS-CoV-2 nucleoprotein (N), spike (S-)protein and the receptor-binding-domain (RBD) of the S-protein. Titers were log-transformed and a multivariate log-linear model with time-since-infection and clinical variables was fitted by Bayesian methods. Results: The mean estimated half-life of the N-antibody was 52 days (95% CI 42-65). The S- and RBD-antibody had significantly longer mean half-lives of 81 days (95% CI 61-111) and 83 days (95% CI 55-137) respectively. An ACE-2-receptor competition assay demonstrated significant correlation between the S and RBD-antibody titers and ACE2-receptor blocking in-vitro. The time-to-a-negative N-antibody test for 50% of the seropositive population was predicted to be 195 days (95% CI 163-236). Discussion: After SARS-CoV-2 infection, the predicted half-life of N-antibody was 52 days with 50% of seropositive participants becoming seronegative to this antibody at 195 days. Widely used serological tests that depend on the N-antibody will therefore significantly underestimate the prevalence of infection following the majority of infections.
Telithromycin 800 mg once daily is a convenient, optimal-spectrum, first-line treatment for CAP in adults, at least as effective and well tolerated as high-dose amoxicillin.
Antibody detection is essential to establish exposure, infection, and immunity to SARS-CoV-2, as well as to perform epidemiological studies. The worldwide urge for new diagnostic tools to control the pandemic has led to a quick incorporation in clinical practice of the recently developed serological assays. However, as only few comparative studies have been published, there is a lack of data about the diagnostic accuracy of currently available assays. We evaluated the diagnostic accuracy to detect Ig G, Ig M+A, and/or IgA anti SARS-CoV-2 of 10 different assays: lateral flow card immunoassays, 4 enzyme-linked immunosorbent assay (ELISA), and 3 chemiluminescent particle immunoassays (CMIA). Using reverse transcriptase polymerase chain reaction (RT-PCR) for COVID-19 as gold standard, sensitivity, specificity, PPV, and NPV were determined. Each assay was tested in 2 groups, namely, positive control, formed by 50 sera from 50 patients with SARS-CoV-2 pneumonia with positive RT-PCR; and negative control, formed by 50 sera from 50 patients with respiratory infection non-COVID-19. Sensitivity range of the 10 assays evaluated for patients with positive COVID-19 RT-PCR was 40-77% (65-81% considering IgG plus IgM). Specificity ranged 83-100%. VPP and VPN were respectively 81-100% and 61.6-81%. Among the lateral flow immunoassays, the highest sensitivity and specificity results were found in Wondfo® SARS-CoV-2 Antibody Test. ELISA IgG and IgA from EUROIMMUN® were the most sensitive ELISA. However, poor results were obtained for isolated detection of IgG. We found similar sensitivity for IgG with SARS-CoV-2 for Architect by Abbott® and ELISA by Vircell®. Results obtained varied widely among the assays evaluated. Due to a better specificity, overall diagnostic accuracy of the assays evaluated was higher in case of positive result. On the other side, lack of antibody detection should be taken with care because of the low sensitivity described. Highest diagnostic accuracy was obtained with ELISA and CMIAs, but they last much longer.
COVID-19 has overloaded national health services worldwide. Thus, early identification of patients at risk of poor outcomes is critical. Our objective was to analyse SARS-CoV-2 RNA detection in serum as a severity biomarker in COVID-19. Retrospective observational study including 193 patients admitted for COVID-19. Detection of SARS-CoV-2 RNA in serum (viremia) was performed with samples collected at 48–72 h of admission by two techniques from Roche and Thermo Fischer Scientific (TFS). Main outcome variables were mortality and need for ICU admission during hospitalization for COVID-19. Viremia was detected in 50–60% of patients depending on technique. The correlation of Ct in serum between both techniques was good (intraclass correlation coefficient: 0.612; p < 0.001). Patients with viremia were older (p = 0.006), had poorer baseline oxygenation (PaO2/FiO2; p < 0.001), more severe lymphopenia (p < 0.001) and higher LDH (p < 0.001), IL-6 (p = 0.021), C-reactive protein (CRP; p = 0.022) and procalcitonin (p = 0.002) serum levels. We defined "relevant viremia" when detection Ct was < 34 with Roche and < 31 for TFS. These thresholds had 95% sensitivity and 35% specificity. Relevant viremia predicted death during hospitalization (OR 9.2 [3.8–22.6] for Roche, OR 10.3 [3.6–29.3] for TFS; p < 0.001). Cox regression models, adjusted by age, sex and Charlson index, identified increased LDH serum levels and relevant viremia (HR = 9.87 [4.13–23.57] for TFS viremia and HR = 7.09 [3.3–14.82] for Roche viremia) as the best markers to predict mortality. Viremia assessment at admission is the most useful biomarker for predicting mortality in COVID-19 patients. Viremia is highly reproducible with two different techniques (TFS and Roche), has a good consistency with other severity biomarkers for COVID-19 and better predictive accuracy.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.