OBJECTIVE:
To compare the efficacy of Icon resin infiltration and Clinpro XT varnish on remineralization of white spot lesions using a polarized light microscope (PLM).
MATERIALS & METHODS:
Artificial white spot lesions were created on a sample of 40 extracted human premolar teeth by immersing in a demineralizing solution. All samples were randomly allocated to two groups of 20 each; Group A: Icon resin infiltration and Group B: Clinpro XT varnish. Teeth were sectioned along the buccolingual plane using a diamond disc. Specimens were observed under the PLM (4× magnification) at three deepest measurements and their averages were calculated to obtain the mean penetration depth. The data obtained were analyzed using SPSS software (version 22.0). Independent samples
t
-test and group statistics were used to compare the two groups. In all statistical tests, the significance level was set at 5% (
P
< 0.05).
RESULTS:
Both Icon resin infiltration and Clinpro XT groups showed a statistically significant difference (
P
= 0.00) in the penetration depth. Icon resin infiltration group showed a significantly higher penetration depth (24.46 μm) compared to the Clinpro XT group (12.34 μm). Group A showed a greater mean penetration depth (17.07 ± 4.35 μm) when compared to group B (7.68 ± 1.81 μm).
CONCLUSION:
Icon resin infiltration showed a significantly higher penetration depth and is more effective on remineralization of white spot lesions when compared to Clinpro XT varnish.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.