Background:Extraarticular distal tibial fractures are among the most challenging fractures encountered by an orthopedician for treatment because of its subcutaneous location, poor blood supply and decreased muscular cover anteriorly, complications such as delayed union, nonunion, wound infection, and wound dehiscence are often seen as a great challenge to the surgeon. Minimally invasive plate osteosynthesis (MIPO) and intramedullary interlocking nail (IMLN) are two well-accepted and effective methods, but each has been historically related to complications. This study compares clinical and radiological outcome in extraarticular distal tibia fractures treated by intramedullary interlocking nail (IMLN) and minimally invasive plate osteosynthesis (MIPO).Materials and Methods:42 patients included in this study, 21 underwent IMLN and 21 were treated with MIPO who met the inclusion criteria and operated between June 2014 and May 2015. Patients were followed up for clinical and radiological evaluation.Results:In IMLN group, average union time was 18.26 weeks compared to 21.70 weeks in plating group which was significant (P < 0.0001). Average time required for partial and full weight bearing in the nailing group was 4.95 weeks and 10.09 weeks respectively which was significantly less (P < 0.0001) as compared to 6.90 weeks and 13.38 weeks in the plating group. Lesser complications in terms of implant irritation, ankle stiffness, and infection, were seen in interlocking group as compared to plating group. Average functional outcome according to American Orthopedic Foot and Ankle Society score was measured which came out to be 96.67.Conclusion:IMLN group was associated with lesser duration of surgery, earlier weight bearing and union rate, lesser incidence of infection and implant irritation which makes it a preferable choice for fixation of extra-articular distal tibial fractures. However, larger randomized controlled trials are required for confirming the results.
Clavicular fractures commonly occur in adults and children. The usual mechanism of injury is a fall on the outstretched hand or direct trauma. The usual site of these fractures is the mid clavicle with lateral end and medial end clavicular fractures being less common, respectively. Segmental clavicular fractures have been reported in the literature; they usually occur at the medial and lateral ends and tend to occur in adults. Bipolar clavicular injuries involving medial and lateral ends have also been reported rarely but all in adults. We report a very rare case of segmental clavicular fracture involving the mid clavicle and lateral end in an adolescent caused by direct trauma. The management of segmental clavicle fractures has not been clearly outlined although operative intervention is indicated. We report the successful management of segmental fracture clavicle in an adolescent and discuss the relevant literature.
We conducted this study to evaluate the use of rail fixation system in infected gap non-union of femur and tibia as an alternative to the established Ilizarov circular fixator technique. Prospective study. The study was done in the Department of Orthopaedic surgery in a medical school and level I trauma center to which the authors are/were affiliated. Between June 2010 and June 2015, 40 patients with infected gap non-union of femur and tibia were treated with the rail fixation system. Patients who were willing to undergo surgery and participate in the post-operative rehabilitation were included in the study. After radical debridement, the system was applied and corticotomy done. For closure of bone gap, acute docking and distraction was done in 18 cases and segmental bone transport in 22 cases. Early mobilization of patient was done along with aggressive physiotherapy. Bone and functional results were calculated according to ASAMI scoring system, and complications were classified according to Paley classification. The mean follow-up period was 22.56 months (range 8–44). Bone union with eradication of infection was achieved in all but 1 case (97.5%). Bone results were excellent in 57.5%, good 40%, fair 0% and poor in 2.5% cases, while functional result was excellent in 32.5%, good 65%, fair 0% and poor in 2.5% cases. The rail fixation system is an excellent alternative method to treat infected gap non-union of femur and tibia. It is simple, easy to use and patient-friendly.
Congenital deficiency of part of distal ulna affecting the distal radio-ulnar joint is a rare disorder. It is even rarer to find the association of proximal radio-ulnar joint dislocation along with distal ulnar deficiency. This type of congenital forearm anomaly is difficult to treat. Conversion to a single bone forearm in the expense of pronation-supination movement is a viable option. By doing so the elbow and wrist can be stabilized; however movement is possible in only one plane. We are describing here a girl of 8 years having proximal radio-ulnar joint dislocation along with deficiency of distal ulna treated by converting into a single bone forearm.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.