Cardiomyocytes derived from human induced pluripotent stem cells (hiPSC-CMs) are an invaluable tool for both basic and translational cardiovascular research. The potential that these cells hold for therapy, disease modeling and drug discovery is hampered by several bottlenecks that currently limit both the yield and the efficiency of cardiac induction. Here, we present a complete workflow for the production of ready-to-use hiPSC-CMs in a dynamic suspension bioreactor. This includes the efficient and highly reproducible differentiation of hiPSCs into cardiospheres, which display enhanced physiological maturation compared to static 3D induction in hanging drops, and a novel papain-based dissociation method that offers higher yield and viability than the broadly used dissociation reagents TrypLE and Accutase. Molecular and functional analyses of the cardiomyocytes reseeded after dissociation confirmed both the identity and the functionality of the cells, which can be used in downstream applications, either as monolayers or spheroids.
Benefits of single molecule studies of biomolecules include the need for minimal amounts of material and the potential to reveal phenomena hidden in ensembles. However, results from recent single molecule studies of fluorescent ATP turnover by myosin are difficult to reconcile with ensemble studies. We found that key reasons are complexities due to dye photophysics and fluorescent contaminants. After eliminating these, through surface cleaning and use of triple state quenchers and redox agents, the distributions of ATP binding dwell times on myosin are best described by 2 to 3 exponential processes, with and without actin, and with and without the inhibitor para-aminoblebbistatin. Two processes are attributable to ATP turnover by myosin and actomyosin respectively, whereas the remaining process (rate constant 0.2–0.5 s−1) is consistent with non-specific ATP binding to myosin, possibly accelerating ATP transport to the active site. Finally, our study of actin-activated myosin ATP turnover without sliding between actin and myosin reveals heterogeneity in the ATP turnover kinetics consistent with models of isometric contraction.
Molecular motor-based nanodevices require organized cytoskeletal filament guiding along motility-promoting tracks, confined by motility-inhibiting walls. One way to enhance motility quality on the tracks, particularly in terms of filament velocity but also the fraction of motile filaments, is to optimize the surface hydrophobicity. We have investigated the potential to achieve this for the actin-myosin II motor system on trimethylchlorosilane (TMCS)-derivatized SiO surfaces to be used as channel floors in nanodevices. We have also investigated the ability to supress motility on two new polymer resists, TU7 (for nanoimprint lithography) and CSAR 62 (for electron beam and deep UV lithography), to be used as channel walls. We developed a chemical-vapor deposition tool for silanizing SiO surfaces in a controlled environment to achieve different surface hydrophobicities (measured by water contact angle). In contrast to previous work, we were able to fabricate a wide range of contact angles by varying the silanization time and chamber pressure using only one type of silane. This resulted in a significant improvement of the silanization procedure, producing a predictable contact angle on the surface and thereby predictable quality of the heavy meromyosin (HMM)-driven actin motility with regard to velocity. We observed a high degree of correlation between the filament sliding velocity and contact angle in the range 10-86°, expanding the previously studied range. We found that the sliding velocity on TU7 surfaces was superior to that on CSAR 62 surfaces despite similar contact angles. In addition, we were able to suppress the motility on both TU7 and CSAR 62 by plasma oxygen treatment before silanization. These results are discussed in relation to previously proposed surface adsorption mechanisms of HMM and their relationship to the water contact angle. Additionally, the results are considered for the development of actin-myosin based nanodevices with superior performance with respect to actin-myosin functionality.
Over the last 25 years, extensive progress has been made in developing a range of nanotechnological applications where cytoskeletal filaments and molecular motors are key elements. This includes novel, highly miniaturized lab on a chip systems for biosensing, nanoseparation etc but also new materials and parallel computation devices for solving otherwise intractable mathematical problems. For such approaches, both actin-based and microtubule-based cytoskeletal systems have been used. However, in accordance with their different cellular functions, actin filaments and microtubules have different properties and interaction kinetics with molecular motors. Therefore, the two systems obviously exhibit different advantages and encounter different challenges when exploited for applications. Specifically, the achievable filament velocities, the capability to guide filaments along nanopatterned tracks and the capability to attach and transport cargo differ between actin- and microtubule-based systems. Our aim here is to systematically elucidate these differences to facilitate design of new devices and optimize future developments. We first review the cellular functions and the fundamental physical and biochemical properties of actin filaments and microtubules. In this context we also consider their interaction with molecular motors and other regulatory proteins that are of relevance for applications. We then relate these properties to the advantages and challenges associated with the use of each of the motor-filament systems for different tasks. Finally, fundamental properties are considered in relation to some of the most interesting future development paths e.g. in biosensing and biocomputation.
Significant advancements have been made towards exploitation of naturally available molecular motors and their associated cytoskeletal filaments in nanotechnological applications. For instance, myosin motors and actin filaments from muscle have been used with the aims to establish new approaches in biosensing and network-based biocomputation. The basis for these developments is a version of the in vitro motility assay (IVMA) where surface-adsorbed myosin motors propel the actin filaments along suitably derivatized nano-scale channels on nanostructured chips. These chips are generally assembled into custom-made microfluidic flow cells. For effective applications, particularly in biocomputation, it is important to appreciably prolong function of the biological system. Here, we systematically investigated potentially critical factors necessary to achieve this, such as biocompatibility of different components of the flow cell, the degree of air exposure, assay solution composition and nanofabrication methods. After optimizing these factors we prolonged the function of actin and myosin in nanodevices for biocomputation from <20 min to >60 min. In addition, we demonstrated that further optimizations could increase motility run times to >20 h. Of great importance for the latter development was a switch of glucose oxidase in the chemical oxygen scavenger system (glucose oxidase–glucose–catalase) to pyranose oxidase, combined with the use of blocking actin (non-fluorescent filaments that block dead motors). To allow effective testing of these approaches we adapted commercially available microfluidic channel slides, for the first time demonstrating their usefulness in the IVMA. As part of our study, we also demonstrate that myosin motor fragments can be stored at −80 °C for more than 10 years before use for nanotechnological purposes. This extended shelf-life is important for the sustainability of network-based biocomputation.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.