We recommend the use of a ring fixator in patients with a bone gap of more than 6 cm. Patients with a bone gap up to 6 cm can be managed with either a ring or rail fixator. Cite this article: Bone Joint J 2016;98B:1399-1405.
Purpose. To report the outcome of fixation for delayed union or non-union posterior cruciate ligament (PCL) avulsion fractures. Methods. Seven men and 4 women aged 24 to 35 (mean, 28) years underwent lag screw or suture fixation for non-union or delayed union of avulsion fracture of PCL tibial attachment after a mean delay of 8.6 (range, 4-14) months. Patient satisfaction was assessed using a visual analogue scale (VAS). Functional outcome was evaluated using the Lysholm scale.Results. The mean follow-up period was 17 (range, 8-36) months. The mean Lysholm score improved from 82 preoperatively to 92 at the final follow-up (p=0.34), the mean range of knee motion improved from 82º to 87º (p=0.008), and the mean VAS score for patient satisfaction improved from 4.3 to 7.4 (p=0.0004). All patients but one achieved bone union after a mean of 7.5 (range, 7-9) weeks. Functional outcome was excellent for 6 patients, good for 4, and fair for one. Posterior drawer test was positive (grade I laxity) in 3 patients whose outcome was good for 2 and fair for one. The latter had non-union after Ethibond suture repair for a communited fracture. There were no instances of wound complications or implant loosening. Conclusion. Fixation with lag screw or suture combined with bone grafting for delayed union or non-union of PCL avulsion fractures achieves acceptable functional outcome.
Introduction. The purpose of this study was to analyze the functional outcome in competitive level athletes at 5 years after ACL reconstruction with regard to return to sports and the factors or reasons in those who either stopped sports or showed a fall in their sporting levels. Methods. 48 competitive athletes who had undergone arthroscopic assisted ACL reconstruction with a minimum follow up of at least 5 years were successfully recalled and were analyzed. Results. 22 patients had returned to the preinjury levels of sports and 18 showed a decrease in their sporting levels. Of the 18 patients, 12 referred to fear of reinjuring the same or contra-lateral knee as the prime reason for the same while 6 patients reported persisting knee pain and instability as reasons for a fall in their sporting abilities. The difference in the scores of these groups was statistically significant. 8 patients out of the 48 had left sports completely due to reasons other than sports, even though they had good knee outcome scores. Conclusion. Fear of reinjury and psychosocial issues that are relevant to the social milieu of the athlete are very important and affect the overall results of the surgery with respect to return to sports.
Background. Dorsally comminuted distal radius fractures are unstable fractures and represent a treatment challenge. The objective of this study was to evaluate the functional and radiological outcome of dorsally comminuted fractures of the distal radius fixed with a volar locking plate. Patients and Methods. Thirty-three consecutive patients with dorsally comminuted fractures of the distal end of the radius were treated by open reduction and internal fixation with AO 2.4 mm (n = 19)/3.5 mm (n = 14) volar locking distal radius plate (Synthes, Switzerland, marketed by Synthes India Pvt. Ltd.). There were 7 type A3, 8 type C2, and 18 type C3 fractures. The patients were followed up at 6 weeks, 3 months, 6 months, and 1 year postoperatively. Subjective assessment was done as per Disabilities Arm, Shoulder, and Hand (DASH) questionnaire. Functional evaluation was done by measuring grip strength and range of motion around the wrist; the radiological determinants were radial angle, radial length, volar angle, and ulnar variance. The final assessment was done as per Demerit point system of Saito. Results. There were 23 males and 10 females with an average age of 44.12 ± 18.63 years (18–61 years). Clinicoradiological consolidation of the fracture was observed in all cases at a mean of 9.6 weeks (range 7–12 weeks). The average final extension was 58.15° ± 7.83°, flexion was 54.62° ± 11.23°, supination was 84.23° ± 6.02°, and pronation was 80.92° ± 5.54°. Demerit point system of Saito yielded excellent results in 79% (n = 26), good in 18% (n = 6), and fair in 3% (n = 1) patients. Three patients had loss of reduction but none of the patients had tendon irritation or ruptures, implant failure, or nonunion at the end of an one-year followup. Conclusion. Volar locking plate fixation for dorsally comminuted distal radius fractures results in good to excellent functional outcomes despite a high incidence of loss of reduction and fracture collapse.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.