A simple, sensitive, specific, and cost effective method for simultaneous determination of Aspirin and Rosuvastatin calcium was developed and validated in single dosage formulation. The sample solution of ASP and RSTC was prepared using methanol as a solvent. Separation of ASP and RSTC was achieved with a mobile phase consisting of 20 mM KH 2 PO 4 : Methanol (30:70 v/v) at a flow rate of 1.0 ml/min. Separations were performed on Merck hibar 250-4.6 RP18 (5 µm) column (150 mm X 3.0 mm), using a Shimadzu Prominence HPLC system equipped with a Shimadzu SPD-20A detector, Rhenodyne 7725i injector with 20 μL loop, LC-20 AD pump, CBM-20 Alite controller and LC Solution software. Retention times of ASP and RSTC were 3.747 and 5.969 minutes respectively. Absolute recovery of ASP and RSTC was 100.3 and 100.03 % respectively. The lower limit of quantification (LLOQ) of ASP and RSTC was 0.3097 and 0.1063 ppm and lower limit of detection (LLOD) of ASP and RSTC was 0.01535 and 0.01358 ppm respectively. Linearity was established for the range of concentrations 15.00-90.0 μg/ml and 2.0-12.0 μg/ml for ASP and RSTC respectively with the coefficient of determination (R 2 ) of 0.994 and 0.999 for both the compounds. The inter-and intra-day precision in the measurement of ASP quality control (QC) sample 75 μg/ml, were in the range 0.1-0.2 % relative standard deviation (R.S.D.) and 0.2-0.3 % R.S.D., respectively. The inter-and intra-day precision in the measurement of RST quality control (QC) sample 10 μg/ml, were in the range 0.1-0.2 % R.S.D., and 0.0-0.3 % R.S.D., respectively. The developed method would be applicable for routine quality control of ASP And RSTC in bulk as well as in pharmaceutical formulations.
A simple, sensitive, specific, and cost effective method for simultaneous determination of Aspirin and Rosuvastatin calcium was developed and validated in single dosage formulation. The sample solution of ASP and RSTC was prepared using methanol as a solvent. Separation of ASP and RSTC was achieved with a mobile phase consisting of 20 mM KH2PO4 : Methanol (30:70 v/v) at a flow rate of 1.0 ml/min. Separations were performed on Merck hibar 250-4.6 RP18 (5 µm) column (150 mm X 3.0 mm), using a Shimadzu Prominence HPLC system equipped with a Shimadzu SPD-20A detector, Rhenodyne 7725i injector with 20 μL loop, LC-20 AD pump, CBM-20 Alite controller and LC Solution software. Retention times of ASP and RSTC were 3.747 and 5.969 minutes respectively. Absolute recovery of ASP and RSTC was 100.3 and 100.03 % respectively. The lower limit of quantification (LLOQ) of ASP and RSTC was 0.3097 and 0.1063 ppm and lower limit of detection (LLOD) of ASP and RSTC was 0.01535 and 0.01358 ppm respectively. Linearity was established for the range of concentrations 15.00-90.0 μg/ml and 2.0-12.0 μg/ml for ASP and RSTC respectively with the coefficient of determination (R2) of 0.994 and 0.999 for both the compounds. The inter- and intra-day precision in the measurement of ASP quality control (QC) sample 75 μg/ml, were in the range 0.1-0.2 % relative standard deviation (R.S.D.) and 0.2-0.3 % R.S.D., respectively. The inter- and intra-day precision in the measurement of RST quality control (QC) sample 10 μg/ml, were in the range 0.1-0.2 % R.S.D., and 0.0-0.3 % R.S.D., respectively. The developed method would be applicable for routine quality control of ASP And RSTC in bulk as well as in pharmaceutical formulations
A novel, stability-indicating high-performance liquid chromatographic (HPLC) method is delivered for the determination of fluphenazine hydrochloride (FPZ) and its degradation products. The forced degradation testing of FPZ was carried out for hydrolytic, oxidative, photolytic, and thermal degradation. The degradation appeared using a reversed-phase C18 column at ambient temperature with a mobile phase comprised of methanol : acetonitrile : (10 mM) ammonium acetate (70:15:15, v/v/v) pH 6.0, adjusted with acetic acid, having a flow rate of 1 ml min−1 and a detection wavelength at 259 nm. Primarily, the maximum degradation products were formed under oxidative stress conditions. The product was distinguished through LC-MS/MS fragmentation studies. Based on the results, a more complete degradation pathway for the drug could be proposed. The modernized method was found to be precise, accurate, specific, and selective. The method was found to be suitable for the quality control of fluphenazine hydrochloride in the tablet as well as in stability-indicating studies.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.