Purpose of Review We aim to provide a comprehensive analysis of hypercoagulability in individuals affected by COVID-19. Our goal is to describe the hypercoagulable state related to the infection and provide guidance regarding the possible benefits of anti-coagulation with the support of evidence from current literature. Recent Findings The incidence of thrombotic disease in individuals affected by COVID-19 is reported as high as 31%. A significant mortality benefit has been observed with the use of therapeutic anticoagulation in high-risk individuals. Literature supports the use of scoring systems, such as the sepsis-induced coagulopathy score, to risk-stratify individuals who might benefit from anticoagulation. Summary COVID-19-induced hypercoagulability has been demonstrated to play a significant role in overall COVID-19 outcomes. Current literature shows promising evidence with the use of therapeutic anticoagulation in high-risk individuals. Further studies are needed to better analyze the risks and benefits of anticoagulation in this specific patient population.
Background:
Interventional therapies aiming at excluding the left atrial appendage (LAA) from systemic circulation have been established as a valid alternative to oral anticoagulation in patients at high thromboembolic risk. However, their efficacy on stroke prophylaxis may be compromised owing to incomplete LAA closure. Additionally, the need for an alternative thromboembolic prevention may remain unmet in patients with contraindications to oral anticoagulation whose appendage anatomy is unsuitable for some conventional devices commercially available. We aimed at evaluating the feasibility of LAA closure with the novel Gore Cardioform Septal Occluder in patients with incomplete appendage ligation or anatomic features which do not meet the manufacturer’s requirements for Watchman deployment.
Methods:
Twenty-one consecutive patients (mean age: 72±6 years; 85.7% males; CHA
2
DS
2
-VASc: 4.5±1.4; HAS-BLED: 3.6±1.0) were included. Transesophageal echocardiography was performed within 2 months to assess for residual LAA patency.
Results:
Fourteen patients had incomplete LAA closure following surgical (n=6) or Lariat ligation (n=8). In 7 patients with an appendage anatomy unsuitable for Watchman deployment, the mean maximal landing zone size and LAA depth were 14.4±1.3and 18.6±2.8 mm. Successful Cardioform Septal Occluder deployment was achieved in all patients. No peri-procedural complications were documented.Procedure and fluoroscopy times were 46±13 and 14±5 minutes. Follow-up transesophageal echocardiography after 58±9 days revealed complete LAA closure in all patients.
Conclusions:
Transcatheter LAA closure via a Cardioform Septal Occluder device might be a valid alternative in patients with residual leaks following failed appendage ligation or whose LAA anatomy does not meet the minimal anatomic criteria to accommodate a Watchman device.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.