Ebola virus (EBOV) remains one of the most lethal transmissible infections and is responsible for high fatality rates and substantial morbidity during sporadic outbreaks. With increasing human incursions into endemic regions and the reported possibility of airborne transmission, EBOV is a high-priority public health threat for which no preventive or therapeutic options are currently available. Recent studies have demonstrated that cocktails of monoclonal antibodies are effective at preventing morbidity and mortality in nonhuman primates (NHPs) when administered as a post-exposure prophylactic within 1 or 2 days of challenge. To test whether one of these cocktails (MB-003) demonstrates efficacy as a therapeutic (after the onset of symptoms), we challenged NHPs with EBOV and initiated treatment upon confirmation of infection according to a diagnostic protocol for U.S. Food and Drug Administration Emergency Use Authorization and observation of a documented fever. Of the treated animals, 43% survived challenge, whereas both the controls and all historical controls with the same challenge stock succumbed to infection. These results represent successful therapy of EBOV infection in NHPs. INTRODUCTIONSince its discovery and initial characterization in the mid-1970s, Ebola virus (EBOV; formerly known as Zaire ebolavirus; genus: Ebolavirus, family: Filoviridae) has remained one of the most virulent and deadly pathogens known. With mortality rates approaching 90%, the virus quickly overwhelms the host, inducing a severe hemorrhagic fever and often death during sporadic outbreaks (1, 2). There are currently no licensed vaccines or therapeutics to prevent or treat infection with EBOV or any filovirus. With the increasing ease and speed of global travel and the potential for viral spread via the aerosol route (3), EBOV is a potential public health threat (4). Classification by the Centers for Disease Control as a category A agent also designates EBOV as a bioterrorism threat, making this virus a biodefense research priority (5).Research has identified phosphorodiamidate morpholino oligomers (PMOs), small interfering RNAs (siRNAs), and a vesicular stomatitis virus (VSV)-based vaccine as potential candidates for post-exposure treatment (6-8). These candidates have shown promising efficacy in reducing mortality when administered to nonhuman primates (NHPs) up to 1 hour after exposure. More recently, antibodies were demonstrated to be highly effective in post-exposure prophylaxis of NHPs against EBOV. Passive transfer of macaque hyperimmune globulin was shown to protect rhesus macaques when dosing began 2 days after exposure (9). Similarly, a cocktail of three murine monoclonal antibodies (mAbs) provided 100 and 50% efficacy in cynomolgus macaques when dosing began 1 or 2 days after exposure, respectively (10). Finally, a cocktail of three mAbs with human constant regions (MB-003) manufactured in Nicotiana benthamiana (11) provided 100 or 67% protection in the rhesus macaque model when treatment began 1 hour or 2 days after expo...
Development and evaluation of medical countermeasures for diagnostics, vaccines, and therapeutics requires production of standardized, reproducible, and well characterized virus preparations. For filoviruses this includes plaque assay for quantitation of infectious virus, transmission electron microscopy (TEM) for morphology and quantitation of virus particles, and real-time reverse transcription PCR for quantitation of viral RNA (qRT-PCR). The ViroCyt® Virus Counter (VC) 2100 (ViroCyt, Boulder, CO, USA) is a flow-based instrument capable of quantifying virus particles in solution. Using a proprietary combination of fluorescent dyes that stain both nucleic acid and protein in a single 30 min step, rapid, reproducible, and cost-effective quantification of filovirus particles was demonstrated. Using a seed stock of Ebola virus variant Kikwit, the linear range of the instrument was determined to be 2.8E+06 to 1.0E+09 virus particles per mL with coefficient of variation ranging from 9.4% to 31.5% for samples tested in triplicate. VC particle counts for various filovirus stocks were within one log of TEM particle counts. A linear relationship was established between the plaque assay, qRT-PCR, and the VC. VC results significantly correlated with both plaque assay and qRT-PCR. These results demonstrated that the VC is an easy, fast, and consistent method to quantify filoviruses in stock preparations.
Polymerase chain reaction (PCR) is commonly used for pathogen detection in clinical and environmental samples. These sample matrices often contain inhibitors of PCR, which is a primary reason for sample processing; however, the purification process is highly inefficient, becoming unacceptable at lower signature concentrations. One potential solution is direct PCR assessment without sample processing. Here, we evaluated nine inhibitor-resistant PCR reagents for direct detection of Francisella tularensis in seven different clinical and environmental samples using an established real-time PCR assay to assess ability to overcome PCR inhibition. While several of these reagents were designed for standard PCR, the described inhibitor resistant properties (ex. Omni Klentaq can amplify target DNA samples of up to 20% whole blood or soil) led to our evaluation with real-time PCR. A preliminary limit of detection (LOD) was determined for each chemistry in whole blood and buffer, and LODs (20 replicates) were determined for the top five chemistries in each matrix (buffer, whole blood, sputum, stool, swab, soil, and sand). Not surprisingly, no single chemistry performed the best across all of the different matrices evaluated. For instance, Phusion Blood Direct PCR Kit, Phire Hot Start DNA polymerase, and Phire Hot Start DNA polymerase with STR Boost performed best for direct detection in whole blood while Phire Hot Start DNA polymerase with STR Boost were the only reagents to yield an LOD in the femtogram range for soil. Although not the best performer across all matrices, KAPA Blood PCR kit produced the most consistent results among the various conditions assessed. Overall, while these inhibitor resistant reagents show promise for direct amplification of complex samples by real-time PCR, the amount of template required for detection would not be in a clinically relevant range for most matrices.
BACKGROUND The Department of Defense (DoD) and the Food and Drug Administration (FDA) have collaboratively worked on a pre–Emergency Use Authorization (pre-EUA) process for in vitro diagnostic (IVD) devices, using FDA's regulatory flexibilities under the EUA authorities. The pre-EUA process enables FDA review of data in anticipation of a request for an EUA, advancing US government public health emergency preparedness efforts. METHODS The IVD device developed to detect Escherichia coli O104:H4, for which an EUA has not been issued, serves as an example to illustrate that process. Specifically, DoD designed real-time PCR assays to target the virulent E. coli strain O104:H4 (etiological agent of the 2011 German outbreak) including: fliC (flagellin), Agg3C (AAF), and rfb (wbwC) on the basis of the published sequences. RESULTS After development and optimization of these 3 specific assays, a defined protocol was followed to determine and document the sensitivity and specificity of each assay analytically. CONCLUSIONS FDA reviewed these data and returned commentary on additional required experiments to complete the pre-EUA process and expedite the use of the device should there be an emergency need for an IVD device to detect this virulent E. coli strain before such a test is cleared by FDA.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2025 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.