This article aimed to examine the clinical and radiographic outcome of mini dental implants (MDIs) supporting a mandibular overdenture. Twenty-eight patients (16 men and 12 women) complaining from insufficient retention of their mandibular denture received a total of 112 MDIs (four per patient) in the interforaminal area of the mandible using the non-submerged flapless surgical approach. Implants were immediately loaded with mandibular overdentures after implant insertion. Each implant was evaluated at the time of initial prosthetic loading, 6, 12, 24 and 36 months thereafter. Clinical evaluation was performed using plaque index (PI), gingival index (GI), probing depth (PD) and periotest values (PTVs). Radiographic evaluation was performed in terms of vertical (VBLO) and horizontal (HBLO) alveolar bone loss. Cumulative success and survival rates were calculated using life table analysis. Plaque index, GI, PD, VBLO and HBLO increased significantly in the first year after overdenture insertion, and no significant difference between subsequent observations was noted. Periotest values demonstrated no significant difference between observation times. The cumulative survival and success rates of MDIs were 96·4% and 92·9%, respectively. Within the limitations of this study, clinical and radiographic peri-implant tissue responses of immediately loaded MDIs supporting a mandibular overdenture were favourable after 3 years. However, randomised, controlled clinical trials are needed to compare these responses to that of conventional-diameter implants.
Within the limitations of this study, regarding the small sample size, it could be concluded that overdentures retained by straight bars on two canine implants and supported by two-first molar implants present a clinical advantage in terms of peri-implant and posterior mandibular bone preservation compared to overdentures supported and retained by cantilevered bars on two canine implants after 5 years.
This study aimed to evaluate the periimplant strain around mesially inclined implants used to retain mandibular overdentures with Locator resilient attachments. Four mandibular edentulous acrylic resin models received two implants in the canine areas with 0°, 5°, 10°, and 20° mesial inclinations. Overdentures were connected to the implants using Locator attachments. Pink nylon inserts (light retention) were used for all implant inclinations, and red inserts were used for 20° inclination (20°red). Four strain gages were bonded on the mesial (M), distal (D), buccal (B), and lingual (L) surfaces of each implant. Peri-implant strains were measured during bilateral and unilateral loading. The 20° inclination showed the highest strain, followed by 10° and 5°, and both 0° and 20°red presented with the lowest strain. Site D was associated with the highest strain, followed by M, B, and L, which showed the lowest strain values. Unilateral loading and the loading side presented with significantly higher strain values than bilateral loading and the nonloading side, respectively. Hence, in this study, strains around the two-implant-retained overdentures with Locator attachments increased with increases in mesial implant angulation, except when red male inserts were used.
PURPOSETo compare the changes in the occlusal vertical dimension, activity of masseter muscles and biting force after insertion of immediate denture constructed with conventional, tooth-supported and Implant-supported immediate mandibular complete denture.MATERIALS AND METHODSPatients were selected and treatment was carried out with all the three different concepts i.e, immediate denture constructed with conventional (Group A), tooth-supported (Group B) and Implant-supported (Group C) immediate mandibular complete dentures. Parameters of evaluation and comparison were occlusal vertical dimension measured by radiograph (at three different time intervals), Masseter muscle electromyographic (EMG) measurement by EMG analysis (at three different positions of jaws) and bite force measured by force transducer (at two different time intervals). The obtained data were statistically analyzed by using ANOVA-F test at 5% level of significance. If the F test was significant, Least Significant Difference test was performed to test further significant differences between variables.RESULTSComparison between mean differences in occlusal vertical dimension for tested groups showed that it was only statistically significant at 1 year after immediate dentures insertion. Comparison between mean differences in wavelet packet coefficients of the electromyographic signals of masseter muscles for tested groups was not significant at rest position, but significant at initial contact position and maximum voluntary clench position. Comparison between mean differences in maximum biting force for tested groups was not statistically significant at 5% level of significance.CONCLUSIONImmediate complete overdentures whether tooth or implant supported prosthesis is recommended than totally mucosal supported prosthesis.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.