PurposeThe posterior cruciate ligament (PCL) presents commonly with avulsion fractures of its tibial attachment. An avulsion fracture of the PCL, if not surgically fixed, may lead to secondary changes in the knee joint. Various fixation techniques have been explored with use of lag screws, steel wires, absorbable screws, suture anchors and straddle nails. The purpose of this study was to evaluate the clinical and functional outcome of open reduction and internal fixation of tibial avulsion injuries of the PCL using cannulated cancellous screws.Materials and MethodsWe performed open reduction and internal fixation using cannulated cancellous screws in 14 patients (mean age, 33.9 years) with isolated PCL avulsion injuries. Patients with a duration of injury more than 12 weeks were excluded. The minimum follow-up period was 12 months. Results were assessed radiologically and clinically. Final functional outcome was assessed using the Lysholm knee scoring system.ResultsThe average follow-up period was 13.5 months. At the final follow-up, all 14 patients achieved fracture union. The average flexion was 121.7°±9.2° with full extension achieved in all patients. Mild instability (1+) was noted in 4 patients. The Lysholm functional score was excellent in 11 patients, good in 2 patients and fair in 1 patient with an average score of 97±7.6.ConclusionsStable early fixation for PCL avulsion injuries with early controlled mobilization provided excellent to good results. However, fixation should not be discouraged for late-presenting patients because good to fair results can be achieved in such cases.
PurposeThe purpose of this study is to describe a method of inserting cement in the femoral head before fixation with dynamic hip screw to prevent screw cut out due to osteoporosis and to evaluate its clinical outcome in these patients.Materials and MethodsIn this prospective study, 30 patients aged 60 years and older with intertrochanteric fracture were included. Bone mineral density was measured. After reaming of the femoral head and neck with a triple reamer and polymethyl methacrylate, bone cement was introduced into the femoral head using a customized nozzle and a barrel fitted on a cement gun. A Richard screw was inserted and the plate was fixed over the femoral shaft. Patients were mobilized and clinical outcomes were rated using the Salvati and Wilson's scoring system.ResultsMore patients included in this study were between 66 and 70 years old than any other age group. The most common fracture according to the Orthopaedic Trauma Association classification was type 31A2.2 (46.7%). The T-score was found to be −2.506±0.22 (mean±standard deviation); all patients were within the range of −2.0 to −2.8. The duration of radiological union was 13.67±1.77 weeks. Salvati and Wilson's scoring at 12 months of follow up was 30.96±4.97. The majority of patients were able to perform their normal routine activities; none experienced implant failure or screw cut out.ConclusionBone cement augmentation may effectively prevent osteoporosis-related hardware complications like screw cut out in elderly patients experiencing intertrochanteric fractures.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.