Background and Aims There are many barriers to kidney transplant and one of them is presence of donor specific antibodies (DSAs) in the recipients. Presence of strong DSA is considered a relative contraindication for kidney transplantation, however, if DSAs are of weak to moderate then desensitization is attempted in many centres with good success rate. Desensitizing such patients can be an acceptable approach to increase the donor pool and facilitating transplants. This is a retrospective analysis of patients who underwent desensitization at our centre after availability of luminex single antigen (LSA) assay Method Between April 2014 and December 2018, 825 patients underwent kidney transplantation at our centre. Patients who were CDC negative but positive FCXM were further analysed with LSA to know the presence and strength of DSAs. Our protocol for desensitization consisted of plasmapheresis (PP) 1.5 volume by double filtration on alternate day and low dose IV IG 100 mg/kg after each PP. Whenever MFI was <1000 and/or FCXM was negative, patient was taken for transplant with thymoglobulin induction of 1.5 mg/kg for 2-3 doses. All patients were maintained on triple immunosuppression consisting of tacrolimus, mycophenolate mofetil and corticosteroids. We did not routinely followed DSAs in these patients post-transplant if there was no clinical indication. All adverse events during follow up including new onset diabetes after transplant (NODAT), infections, acute rejections (AR), graft loss and death Results Out of 825 patients, 15 underwent HLA incompatible transplants, of which, 8 were males. All patients were first transplant and 11/13 had history of some sensitizing events in the form of blood transfusion and/or pregnancy. The mean dialysis duration was 8.6 ±14.6 months. FCXM was positive in all the patients with 5 patients had T cell flow positive, 8 had B cell flow positive and 2 had both T & B cell FCXM positivity. Most patients had weak to moderate positive flow cross match. On further evaluation by LSA, all these patients had DSAs, with 3/15 had MFI <1000, 6 had MFI between1000-2000, and remaining 6 had MFI >2000, out of which one patient had MFI of 7195 and six patients had multiple DSAs. These patients underwent desensitization with PP and IVIG and the end point of treatment was either MFI < 1000 or FCXM negative. Post- transplant DSAs were done in patients with high MFI or clinically indicated. Two patients had increase in post-transplant DSA titres requiring post-transplant plasmapheresis. The mean follow up was 29±6 months. On follow up, only 1 patient developed borderline cellular rejection one year after transplant, which responded with pulse steroids. Three patients had biopsy for asymptomatic rise in creatinine but it showed patchy ATN with no evidence of rejection.. One patient developed transient CMV viremia, one patient developed lymph node tuberculosis (TB) and two patients had UTI, all of them responded to treatment. There was no graft or patient loss till last follow up. Conclusion This study shows that HLA desensitisation is feasible and successful in if patients are selected carefully and evaluate thoroughly. HLA incompatible transplant can provide a new lease of life to those patients who would otherwise not get a kidney due to lack of paired exchange and deceased donor program
The non-sinusoidal transforms with orthogonal functions consists of Hadamard, Walsh, and Haar function. These nonsinusoidal orthogonal functions consists of either square or rectangular waves. The basis function of this transforms are not sinusoidal. A next level of advancement to the theory of transforms is given by the triangular basis function. The triangular basis function and its use in image transform is discussed in the paper and also the orthogonal matrix for the basis function is discussed for transform. General TermsAlgorithm for Image transform based on triangular wave, data compression. Data sharing and watermarking.
Background: There is little experience of human leucocyte antigen (HLA) desensitization in India based on the Luminex single-antigen bead (SAB) testing. We retrospectively analyzed our patients, who underwent HLA desensitization based on Luminex SAB results. Method: Between 2014 and 2018, patients with complement-dependent cytotoxicity cross-match (CDC-XM) negativity but flow cytometry crossmatch (FC-XM) positivity were further analyzed with Luminex SAB for donor-specific antibodies (DSAs). A total of 12 patients who had DSA mean fluorescent intensity (MFI) of >1000 and <10,000 were included in the study. Our protocol for desensitization consisted of plasmapheresis (PP) followed by low dose intravenous immunoglobulin (IV IG) 100 mg/kg and induction with antithymocyte globulin (ATG). Patients were taken for transplant when either MFI was <1000 and/or FC-XM was negative. Results: All 12 patients were first transplant and 10 had a history of some sensitizing event; pregnancy in 4, blood transfusions in 4, and both in 2 patients. FC-XM was positive for T-cell in 4, B-cell in 6, and both in 2 patients. On evaluation by Luminex SAB, 6 patients had MFI from 1000 to 2000, and 6 had MFI of >2000. All underwent desensitization successfully. Two patients had an increase in posttransplant DSA titers requiring posttransplant PP. The mean follow-up was 26.6 ± 13.9 months. On follow-up, only one patient developed acute T cell-mediated rejection 1 year after transplant, which responded to pulse steroids. There was no graft or patient loss until the last follow-up. Conclusion: This study shows that HLA desensitization is feasible and successful in the Indian setting if patients are properly selected.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.