We present the first in vivo cross-sectional conductivity image of the human leg with 1.7 mm pixel size using the magnetic resonance electrical impedance tomography (MREIT) technique. After a review of its experimental protocol by an Institutional Review Board (IRB), we performed MREIT imaging experiments of four human subjects using a 3 T MRI scanner. Adopting thin and flexible carbon-hydrogel electrodes with a large surface area and good contact, we could inject as much as 9 mA current in a form of 15 ms pulse into the leg without producing a painful sensation and motion artifact. Sequentially injecting two imaging currents in two different directions, we collected induced magnetic flux density data inside the leg. Scaled conductivity images reconstructed by using the single-step harmonic B(z) algorithm well distinguished different parts of the subcutaneous adipose tissue, muscle, crural fascia, intermuscular septum and bone inside the leg. We could observe spurious noise spikes in the outer layer of the bone primarily due to the MR signal void phenomenon there. Around the fat, the chemical shift of about two pixels occurred obscuring the boundary of the fat region. Future work should include a fat correction method incorporated in the MREIT pulse sequence and improvements in radio-frequency coils and image reconstruction algorithms. Further human imaging experiments are planned and being conducted to produce conductivity images from different parts of the human body.
Magnetic resonance electrical impedance tomography (MREIT) aims to produce high-resolution cross-sectional images of conductivity distribution inside the human body. Injected current into an imaging object induces a distribution of internal magnetic flux density, which is measured by using an MRI scanner. We can reconstruct a conductivity image based on its relation with the measured magnetic flux density. In this paper, we explain the contrast mechanism in MREIT by performing and analyzing a series of numerical simulations and imaging experiments. We built a stable conductivity phantom including a hollow insulating cylinder with holes. Filling both inside and outside the hollow cylinder with the same saline, we controlled ion mobilities to create a conductivity contrast without being affected by the ion diffusion process. From numerical simulations and imaging experiments, we found that slopes of induced magnetic flux densities change with hole diameters and therefore conductivity contrasts. Associating the hole diameter with apparent conductivity of the region inside the hollow cylinder with holes, we could experimentally validate the contrast mechanism in MREIT. Interpreting reconstructed apparent conductivity images of the phantom as ion mobility images, we discuss the meaning of the apparent conductivity seen by a certain probing method. In designing MREIT imaging experiments, the ion mobility imaging method using the proposed stable conductivity phantom will enable us to estimate a distinguishable conductivity contrast for a given set of imaging parameters.
Latest experimental results in magnetic resonance electrical impedance tomography (MREIT) demonstrated high-resolution in vivo conductivity imaging of animal and human subjects using imaging currents of 5 to 9 mA. Externally injected imaging currents induce magnetic flux density distributions, which are affected by a conductivity distribution. Since we extract the induced magnetic flux density images from MR phase images, it is essential to reduce noise in the phase images. In vivo human and disease model animal experiments require reduction of imaging current amplitudes and scan times. In this article, we investigate a multi-echo based MREIT pulse sequence where we utilize a remaining time after the first echo within one TR to obtain more echo signals. It also allows us to prolong the total current injection time. From phantom and animal imaging experiments, we found that this method significantly reduces the noise level in measured magnetic flux density images. We describe experimental validation of the multi-echo sequence by comparing its performance with a single-echo method using 3 mA imaging currents. The proposed method will be advantageous for an imaging region with long T2 values such as the brain and knee. Depending on T2 values, we suggest using two or three echoes in future experimental studies. Magn Reson Med 66:957-965, 2011. V C 2011 Wiley-Liss, Inc.
Magnetic resonance electrical impedance tomography (MREIT) is a new bio-imaging modality providing cross-sectional conductivity images from measurements of internal magnetic flux densities produced by externally injected currents. Recent experimental results of postmortem and in vivo imaging of the canine brain demonstrated its feasibility by showing conductivity images with meaningful contrast among different brain tissues. MREIT image reconstructions involve a series of data processing steps such as k-space data handling, phase unwrapping, image segmentation, meshing, modelling, finite element computation, denoising and so on. To facilitate experimental studies, we need a software tool that automates these data processing steps. In this paper, we summarize such an MREIT software package called CoReHA (conductivity reconstructor using harmonic algorithms). Performing imaging experiments of the postmortem canine abdomen, we demonstrate how CoReHA can be utilized in MREIT. The abdomen with a relatively large field of view and various organs imposes new technical challenges when it is chosen as an imaging domain. Summarizing a few improvements in the experimental MREIT technique, we report our first conductivity images of the postmortem canine abdomen. Illustrating reconstructed conductivity images, we discuss how they discern different organs including the kidney, spleen, stomach and small intestine. We elaborate, as an example, that conductivity images of the kidney show clear contrast among cortex, internal medulla, renal pelvis and urethra. We end this paper with a brief discussion on future work using different animal models.
Purpose: To establish multi-modal imaging for the assessment of kidney pH, perfusion, and clearance rate using magnetic resonance imaging (MRI) and multispectral optoacoustic tomography (MSOT) in healthy mice. Kidney pH and perfusion values were measured on a pixel-by-pixel basis using the MRI acidoCEST and FAIR-EPI methods. Kidney filtration rate was measured by analyzing the renal clearance rate of IRdye 800 using MSOT. To test the effect of one imaging method on the other, a set of 3 animals were imaged with MSOT followed by MRI, and a second set of 3 animals were imaged with MRI followed by MSOT. In a subsequent study, the reproducibility of pH, perfusion, and renal clearance measurements were tested by imaging 4 animals twice, separated by 4 days. The contrast agents used for acidoCEST based pH measurements influenced the results of MSOT. Specifically, the exponential decay time from the kidney cortex, as measured by MSOT, was significantly altered when MRI was performed prior to MSOT. However, no significant difference in the cortex to pelvis area under the curve (AUC) was noted. When the order of experiments was reversed, no significant differences were noted in the pH or perfusion values. Reproducibility measurements demonstrated similar pH and cortex to pelvis AUC; however, perfusion values were significantly different with the cortex values being higher and the pelvic values being lower in the second imaging time. We demonstrate that using a combination of MRI and MSOT, physiological measurements of pH, blood flow, and clearance rates can be measured in the mouse kidney in the same imaging session.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.