INTRODUCTION: Each dialysis session uses approximately 150 to 200 L of water [1]. While this was an issue discussed by policymakers and environmentalists, the winter storm that swept across the southwest United States in February 2021 made the bedside physician keenly aware of the problem. The region saw an unprecedented disruption of water and power supplies which put end-stage renal disease (ESRD) patients in jeopardy. Intermittent hemodialysis (IHD) could not be performed due to lack of running water, low water pressures, and unsanitary water conditions. We present 4 cases when continuous renal replacement therapy (CRRT) was utilized to provide urgent hemodialysis in hemodynamically stable, non-critically ill ESRD patients during this time of water supply crisis. CASE PRESENTATION:Our patients were between the ages 47-62 years old, mostly male. All patients were ESRD patients on IHD three days per week. Shortness of breath was the presenting complaint in 3 of 4 patients, each of whom had missed their last scheduled HD session due to inclement weather. 1 of 4 patients presented with altered mental status. Indications for hemodialysis included volume overload with pulmonary edema and respiratory distress, hypertensive crisis, refractory hyperkalemia, and uremic encephalopathy. The CRRT equipment used included the PRISMAX system for CRRT with M150 filters. Renal replacement solution containing 32 mEq/L bicarbonate, 4 mEq/L potassium, and 2.5 mEq/L calcium was used as dialysate fluid. Continuous veno-venous hemodialysis (CVVHD) more was used with a dialysate flow rate of 6L /hour and a blood flow rate of 200/per hour with calculated urea clearance of 100 ml/min. The duration of treatment was 8 hours to achieve the target Kt/V of 1.15, comparable to the recommended 1.2 provided by IHD. 9-10 bags of dialysate were used per each session. Fluid removal ranged from 150-500 ml/hr. 1 patient required a repeat session on a subsequent day due to incomplete treatment due to filter clotting. All patients tolerated the procedure well with the resolution of their acute conditions and normalization of blood pressure and electrolytes. 1 patient developed brief hypotension which resolved with fluid administration. No other adverse events were seen.DISCUSSION: CRRT has typically been used for renal replacement therapy in critically ill patients. It requires specialized equipment and a higher nurse: patient ratio as compared to IHD but can be used to manage volume overload and electrolyte derangements in ESRD patients without the substantial water requirements of IHD. CONCLUSIONS:We demonstrate limited CRRT as an alternative to safely manage ESRD patients needing urgent hemodialysis in the scenario of a natural disaster resulting in a water outage.
PurposeTo compare the accuracy and precision of a conventional intraocular syringe to the Suh precision syringe (SPS), a new injection device designed to decrease operator error and to reduce adverse outcomes by providing a more ergonomic technique for periocular and intraocular injections.MethodsParticipants were instructed to inject a specified quantity of water into a 0.2 mL polymerase chain reaction (PCR) tube and a sheep eye, first with the conventional syringe, and then with the SPS. The degree of needle movement during injection was video recorded and analyzed for forward-retraction movement and variability in movement. The volume of water injected into the PCR tube was also documented. Data was analyzed using a Wilcoxon signed-rank test.ResultsAs compared to the conventional syringe, the SPS had significantly less forward-retraction movement when injecting into the sheep eye (P=0.04). Similarly, the forward-retraction movement of the needle when injecting into the PCR tube was less while using the SPS compared with the conventional syringe; however, this was not statistically significant (P=0.09). There was no significant difference in the volume of water expelled from both syringes (P=0.28).ConclusionThe SPS demonstrates significant potential to decrease the overall risk involved with injections through reduction of forward-retraction movement during device operation. This new syringe design also provides better control with injection depth and drug injection volume. With its more ergonomic design, the SPS has the potential to decrease risks associated with intraocular injections by improving the accuracy and precision of the injection.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2025 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.