Background. In the background of the current COVID-19 pandemic, serological tests are being used to assess past infection and immunity against SARS-CoV-2. This knowledge is paramount to determine the transmission dynamics of SARS-CoV-2 through the post pandemic period. Several individuals belonging to households with an index COVID-19 patient, reported symptoms of COVID-19 but discrepant serology results. Methods. Here we investigated the humoral and cellular immune responses against SARS-CoV-2 in seven families, including nine index patients and eight contacts, who had evidence of serological discordances within the households. Ten unexposed healthy donors were enrolled as controls. Results. All index patients recovered from a mild COVID-19. They all developed anti-SARS-CoV-2 antibodies and a significant T cell response detectable up to 69 days after symptom onset. Six of the eight contacts reported COVID-19 symptoms within 1 to 7 days after the index patients but all were SARS-CoV-2 seronegative. Six out of eight contacts developed a SARS-CoV-2-specific T cell response against structural and/or accessory proteins that lasts up to 80 days post symptom onset suggesting a past SARS-CoV-2 infection. Conclusion. Exposure to SARS-CoV-2 can induce virus-specific T cell responses without seroconversion. T cell responses may be more sensitive indicators of SARS-Co-V-2 exposure than antibodies. Our results indicate that epidemiological data relying only on the detection of SARS-CoV-2 antibodies may lead to a substantial underestimation of prior exposure to the virus
The cilgavimab−tixagevimab combination retains a partial in vitro neutralizing activity against the current SARS‐CoV‐2 variants of concern (omicron BA.1, BA.1.1, and BA.2). Here, we examined whether preexposure prophylaxis with cilgavimab−tixagevimab can effectively protect kidney transplant recipients (KTRs) against the omicron variant. Of the 416 KTRs who received intramuscular prophylactic injections of 150 mg tixagevimab and 150 mg cilgavimab, 39 (9.4%) developed COVID‐19. With the exception of one case, all patients were symptomatic. Hospitalization and admission to an intensive care unit were required for 14 (35.9%) and three patients (7.7%), respectively. Two KTRs died of COVID‐19‐related acute respiratory distress syndrome. SARS‐CoV‐2 sequencing was carried out in 15 cases (BA.1, n = 5; BA.1.1, n = 9; BA.2, n = 1). Viral neutralizing activity of the serum against the BA.1 variant was negative in the 12 tested patients, suggesting that this prophylactic strategy does not provide sufficient protection against this variant of concern. In summary, preexposure prophylaxis with cilgavimab−tixagevimab at the dose of 150 mg of each antibody does not adequately protect KTRs against omicron. Further clarification of the optimal dosing can assist in our understanding of how best to harness its protective potential.
Background: The serologic response of individuals with mild forms of SARS-CoV-2 infection is poorly characterized. Methods: Hospital staff who had recovered from mild forms of PCR-confirmed SARS-CoV-2 infection were tested for anti-SARS-CoV-2 antibodies using two assays: a rapid immunodiagnostic test (99.4% specificity) and the S-Flow assay (~99% specificity).The neutralizing activity of the sera was tested with a pseudovirus-based assay. Results: Of 162 hospital staff who participated in the investigation, 160 reported SARS-CoV- 2 infection that had not required hospital admission and were included in these analyses. The median time from symptom onset to blood sample collection was 24 days (IQR: 21-28, range 13-39). The rapid immunodiagnostic test detected antibodies in 153 (95.6%) of the samples and the S-Flow assay in 159 (99.4%), failing to detect antibodies in one sample collected 18 days after symptom onset (the rapid test did not detect antibodies in that patient). Neutralizing antibodies (NAbs) were detected in 79%, 92% and 98% of samples collected 13-20, 21-27 and 28-41 days after symptom onset, respectively (P=0.02). Conclusion: Antibodies against SARS-CoV-2 were detected in virtually all hospital staff sampled from 13 days after the onset of COVID-19 symptoms. This finding supports the use of serologic testing for the diagnosis of individuals who have recovered from SARS-CoV-2 infection. The neutralizing activity of the antibodies increased overtime. Future studies will help assess the persistence of the humoral response and its associated neutralization capacity in recovered patients.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2025 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.