In pigs, latissimus dorsi musculocutaneous island flaps and buttock skin island flaps were raised. Subcutaneous (PscO2) and intramuscular oxygen tension (PimO2) were measured using a non-heated needle electrode before, during and after repeated occlusion of the supplying artery or the draining vein. During arterial and venous occlusion, the tissue oxygen tension in the musculocutaneous flap dropped rapidly. A plateau was reached after 15 min. After arterial occlusion the mean value was 20 mmHg (SEM = +/- 5 mmHg, N = 6) in the subcutis and 16 mmHg in the muscle (SEM = +/- 4 mmHg, N = 10). After venous occlusion the mean value was 11 mmHg (SEM = +/- 3 mmHg, N = 6) in the subcutis. In the skin flap the drop of PscO2 was slower, and after 30 min of arterial occlusion the mean value was 29 mmHg (SEM = +/- 9 mmHg, N = 6). This study has shown that tissue oxygen tension measurement can be used as a sensitive indicator of acute impairment of the supplying vessels in island flaps. The method seems to have potential for monitoring free tissue transfers. A comparable decrease in PscO2 was found for arterial and venous impairment.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.