SUMMARYPurpose: High-frequency oscillations (HFOs), termed ripples at 80-200 Hz and fast ripples (FRs) at >200/250 Hz, recorded by intracranial electroencephalography (EEG), may be a valuable surrogate marker for the localization of the epileptogenic zone. We evaluated the relationship of the resection of focal brain regions containing high-rate interictal HFOs and the seizure-onset zone (SOZ) determined by visual EEG analysis with the postsurgical seizure outcome, using extraoperative intracranial EEG monitoring in pediatric patients and automated HFO detection. Methods: We retrospectively analyzed 28 pediatric epilepsy patients who underwent extraoperative intracranial video-EEG monitoring prior to focal resection. Utilizing the automated analysis, we identified interictal HFOs during 20 min of sleep EEG and determined the brain regions containing high-rate HFOs. We investigated spatial relationships between regions with high-rate HFOs and SOZs. We compared the size of these regions, the surgical resection, and the amount of the regions with high-rate HFOs/ SOZs within the resection area with seizure outcome.Key Findings: Ten patients were completely seizure-free and 18 were not at 2 years after surgery. The brain regions with high-rate ripples were larger than those with high-rate FRs (p = 0.0011) with partial overlap. More complete resection of the regions with high-rate FRs significantly correlated with a better seizure outcome (p = 0.046). More complete resection of the regions with high-rate ripples tended to improve seizure outcome (p = 0.091); however, the resection of SOZ did not influence seizure outcome (p = 0.18). The size of surgical resection was not associated with seizure outcome (p = 0.22-0.39). Significance: The interictal high-rate FRs are a possible surrogate marker of the epileptogenic zone. Interictal ripples are not as specific a marker of the epileptogenic zone as interictal FRs. Resection of the brain regions with high-rate interictal FRs in addition to the SOZ may achieve a better seizure outcome.
Summary:Purpose: To characterize the spatial and temporal course of ictal high-frequency oscillations (HFOs) recorded by subdural EEG in children with intractable neocortical epilepsy.Methods: We retrospectively studied nine children (four girls, five boys; 4-17 yr) who presented with intractable extrahippocampal localization-related epilepsy and who underwent extraoperative video subdural EEG (1000 Hz sampling rate) and cortical resection. We performed multiple band frequency analysis (MBFA) to evaluate the frequency, time course, and distribution of ictal HFOs. We compared ictal HFO changes before and after clinical onset and postsurgical seizure outcomes.Results: Seventy-eight of 79 seizures showed HFOs. We observed wide-band HFOs (∼250Hz, ∼120 electrodes) in six patients either with partial seizures alone (three patients) or with epileptic spasms (three patients). Three patients with partial seizures that secondarily generalized had wide-band HFOs (∼170 Hz) before clinical onset and sustained narrow-band HFOs (60-164 Hz) with electrodecremental events after clinical onset (∼28 electrodes). In four postoperatively seizure-free patients, more electrodes recorded higher-frequency HFOs inside the resection area than outside before and after clinical seizure onset. In five patients with residual seizures, electrodes recorded more HFOs that were of higher or equal frequency outside the surgical area than inside after clinical onset.Conclusion: For partial seizures alone and epileptic spasms, more electrodes recorded only wide-band HFOs; for partial seizures that secondarily generalized, fewer electrodes recorded wide-band HFOs, but in these seizures electrodes also recorded subsequent sustained narrow-band ictal HFOs. Resection of those brain regions having electrodes with ictal, higher HFOs resulted in postsurgical seizure-free outcomes. Key Words: Ictal high-frequency oscillations-Neocortical epilepsy-Subdural EEG-Multiple band frequency analysis.High-frequency oscillations (HFOs) occur during intracranial EEG at the onset of neocortical seizures in patients with extrahippocampal partial epilepsy (Allen et al
Summary Purpose: Continuous electroencephalography (EEG) monitoring is a valuable tool for the detection of seizures among critically ill children, in particular when these seizures occur without clinical signs: termed nonconvulsive seizures. Continuous EEG monitoring is a limited resource in many centers. We sought to identify which critically ill children most frequently experience nonconvulsive seizures, and thus may particularly benefit from continuous EEG monitoring. Methods: Single‐center review was undertaken of consecutive diagnostic continuous EEG (cEEG) recordings performed in our pediatric and neonatal intensive care units (ICUs). We examined the indications for monitoring, the clinical characteristics of monitored patients, the occurrence and timing of seizures, and clinical and EEG characteristics associated with nonconvulsive seizures. Key Findings: One hundred twenty‐one patients underwent diagnostic continuous EEG monitoring, for a mean duration of 26 h. Seizures were detected in 32% of these patients, of which 90% experienced some nonconvulsive seizures, and 72% experienced exclusively nonconvulsive seizures. Patients with nonconvulsive seizures had significantly greater odds of having acute epilepsy, acute structural brain injury, prior in‐hospital convulsive seizures, and the presence of interictal epileptiform abnormalities on EEG. Significance: Seizures are common among critically ill children undergoing diagnostic cEEG monitoring. The great majority of these seizures are nonconvulsive, requiring EEG for their detection. Predictors of nonconvulsive seizures include acute epilepsy, acute structural brain injury, prior in‐hospital convulsive seizures, and interictal epileptiform abnormalities on EEG. These findings can help inform future allocation of limited cEEG monitoring resources to those patients at greatest risk for nonconvulsive seizures.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.