In this article, we analyzed the structure of human nails to develop a modern biometric authentication system based on the nail bed and finger lunula. The results of the studies on the collected images proved that each fingernail has distinctive characteristics in terms of the length and width of the nail and the lunula, even identical twins. We focused on the fingernail of the right thumb because of its large size and the accuracy and clarity of the nail. The mediation of the indicative points on the nail bed and on the lunula was used to form the pentagonal structure and use it as a region of interest. Then an ensemble independent component analysis, principal component analysis, haar wavelet, and scale invariant feature transformation, were used. Later we classified these algorithms using support vector machine and Naive Bayes techniques, the performance of each algorithm was analyzed by feature extraction with two classifiers. This study was conducted on 100 participants and showed that this new method could be used as a biometric identification system for humans. There was no similarity in results for all verified samples.
This article introduces a new approach for modern applications of medical devices using shape memory polymers to aid in the rehabilitation of muscles and injuries attached to severe fractures. The group of heaters connected with the splint controls the temperature and humidity inside the affected area. Microcontrollers were attached to the polymer plate in order to directly control the required parameters and changes in addition to giving direct commands to the connected sensors. Because of the property of changing the outer shape of the polymer after being exposed to a certain temperature and returning to the normal shape after the removal of the external influence, the designed polymer plate applies light intermittent pressure on the wound area, muscles, and surrounding tissues, which helps to speed up the rehabilitation of these muscles, especially after She suffered from stiffness due to lack of movement during the period of treatment.
<span lang="EN-US">People with broken bones suffer from symptoms of muscular atrophy as a result of a lack of movement, so it was necessary to find effective solutions due to the relative pain they cause and the difficulty of movement after healing. In this paper, we proposed a smart splint made of nickel-titanium shape memory alloys (SMA) wires. These alloys have unique properties compared to other materials, the most important of which is maintaining the original shape during manufacturing at a certain temperature. Temperature, pressure, as well as humidity, were analyzed and monitored while the patient wore the splint to reach the best possible results by using a microcontroller. The results showed that there was a significant improvement for the muscles in a short time when using the proposed splint, as the percentage of qualified muscle recovery increased by more than 70% when using the usual splint. The wires used had an effective role in rehabilitating these muscles by performing a permanent local massage. due to the different diameters of these wires, a different response to temperature change was recorded.</span>
An efficiency of cochlea has a significant contribution in a quality of human hearing and in a language development of newborn. The efficiency of cochlea clinically measured using Distortion Product Otoacoustic Emission (DPOAE). The measurement mainly restricted by acoustic interferences that disrupt response estimation. The disrupted estimation gives rise to repetition in measurement for many times or probably inaccurate efficiency assessment. In this study, investigation of cochlea response estimation was considered based on signal processing (SP), which was regarded as preliminary step toward interference reduction. An in-vivo measurement was performed on a left ear of 36 years old female with normal hearing, where cochlea stimulation and response recording was conducted using personal computer sound card in conjunction of sensitive probe system of ER-10C. The response signals were recorded and then analyzed off-line using SP of Fast Fourier Transform (FFT) and Band Pass-Finite Impulse Response (BP-FIR) filter. Results show that DPOAE frequency components can be extracted using proposed SP method at interference-free situation, where BP-FIR parameters of bandwidth 50Hz-200Hz and order 32-2048 have to be adjusted based on stimulation parameters. The findings dedicate useful investigated parameters for real-time implementation, and for further SP development at interference situation.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.