Background: To evaluate whether EQD2(α/β = 3Gy) at 2 cm3 of the most exposed area of the vagina is related to late vaginal toxicity in postoperative endometrial cancer (PEC) patients (p) treated with exclusive brachytherapy (BT). Methods: From 2014 to 2017, 43p were included in this study. BT was administered: 3-fractions of 6Gy in 37p and 2-fractions of 7.5Gy in 6p. The dose was prescribed at a depth of 5 mm from the applicator surface with dose-point optimization based on distance. The active treatment length was 2.5 cm. CTV-D90 and the dose to the most exposed 2 cm3 of the vagina was calculated for each patient. Late toxicity of the bladder and rectum was assessed using Radiation Therapy Oncology Group (RTOG) criteria, and vaginal toxicity by objective Late Effects Normal Tissue Task Force (LENT)-Subjective, Objective, Management, Analytic (SOMA) (LENT-SOMA) criteria. Statistics: frequency tables, mean, median, range, standard deviation, and box plot. Results: The median follow-up was 51 months (12–68). 20 p (46.5%) and 2 p (4.7%) developed G1 and G2 vaginal complications, respectively. Only 1/2 p-G2 receiving EQD2(α/β = 3Gy) at 2 cm3 >68Gy presented vaginal shortening and 18/20 p-G1 received doses < 68Gy. Conclusions: PECp receiving exclusive brachytherapy with doses < 68Gy EQD2(α/β = 3Gy) at 2 cm2 of the vagina presented only G0–G1 vaginal toxicity, except for one with bleeding telangiectasias. Larger prospective studies are necessary to confirm the present results.
Purpose
To evaluate the preliminary results of the use of 68 Gy EQD2(α/β=3 Gy) as a dose limit to the lowest dose in the most exposed 2 cm3 of the vagina in order to reduce G2 late vaginal problems in postoperative endometrial carcinoma (EC).
Methods
From November 2016 to October 2019, 69 postoperative EC patients receiving vaginal brachytherapy (VBT) ± external beam radiotherapy (EBRT) were prospectively analyzed. The median EBRT dose was 45 Gy (range: 44–50.4 Gy), 1.8−2 Gy/day, 5 fractions(Fr)/week. VBT was administered with the following schedule: 1Fr of 7 Gy after EBRT and 2 daily Fr × 7.5 Gy in exclusive VBT. The dose was prescribed at 0.5 cm from the applicator surface with an active length of 2.5 cm; 56 patients were treated with vaginal cylinders (49–3.5 cm, 6–3 cm, and 1–2.5 cm) and 13 with the colpostat technique. The overall VBT dose was adjusted to meet the vaginal restriction of < 68 Gy EQD2(α/β=3 Gy) at 2 cm3. Late toxicity was prospectively assessed using RTOG scores for bladder and rectum, and the objective LENT-SOMA criteria for vagina.
Results
With a median follow-up of 31.0 months, no vaginal-cuff recurrences were found. Late toxicity: only 1G1(1.4%) rectal toxicity; 21G1(30.4%) and 3G2(4.3%) vaginal complications. Only one (1.4%) of 3 G2 manifested as vaginal shortening.
Conclusions
In postoperative EC patients treated with VBT, only one developed G2 vaginal stenosis with the use of 68 Gy EQD2(α/β=3 Gy) as a dose constraint. These preliminary results seem to indicate the value of this dose limit for reducing G2 vaginal stenosis. Nonetheless, these findings should be confirmed in a larger number of patients with longer follow-up.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.