This paper proposes an advanced artificial intelligence protection technique based on low voltage ride-through (LVRT) for a large-scale doubly fed induction generator (DFIG) wind farm. The proposed protection technique consists of two dependant approaches. The first approach is fault detector algorithm that using adaptive neuro fuzzy inference system as an artificial intelligence technique to detect the fault occurrence and its location. The second approach is implementation of Egyptian LVRT grid code to discriminate between tripping or not tripping decision for faulted wind turbine generators based on fault conditions such as its duration and voltage level. The proposed protection technique is applied on a simulation model of 200 MW Gabal El-Zayt wind farm, which located in Red Sea region and connected to Egyptian electrical grid. The studied wind farm consists of 100 DFIG wind turbines, and each generator has a capacity of 2 MW. The simulation model of studied wind farm is implemented by using MATLAB/SIMULINK toolboxes to demonstrate the performance of proposed protection technique. The impacts of fault duration, fault type, internal and external fault locations on the behaviour of studied wind farm equipped with the proposed protection technique are investigated. Also, the impacts of grid voltage sag and different ground transition resistances on the performance of proposed protection technique are investigated. The simulation results show that, the proposed protection technique can detect and isolate the faulted area according to Egyptian LVRT grid code requirements for enhancement the stability of studied wind farm.
This paper proposes constant active and reactive power control of a wind farm during gust using the supercapacitor (SC) and static synchronous compensator (STATCOM). The proposed technique is applied to Gabal El-Zayt wind farm which located in Red Sea region of Egypt with a capacity of 200 MW and equipped with doubly fed induction generators (DFIGs) and analyzed during gust wind. As the nature of wind is varying all time, the output power is changing continuously so energy storage system such as SC is required. SC is responsible for maintaining constant output active power by charging when there is excess in the output power of DFIG and discharging when there is a lack in the output power of DFIG. Reactive power compensation is achieved by connecting STATCOM to the power system. SC keeps reactive power constant however its value is improved by connecting STATCOM. Wind farm model is analyzed during gust with the proposed technique while active and reactive power performance is investigated. Firstly, the effect of connecting SC to each wind turbine is studied. Then the effect of connecting STATCOM to the electric power system is studied. Also, the effect of connecting SCs and STATCOM is studied. Finally, the impact of connecting additional STATCOM at different locations is investigated. Results show the proposed technique validity.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.