In recent years, high-performance liquid chromatography (HPLC) with tandem mass spectrometric (MS/MS) detection has been demonstrated to be a powerful technique for the quantitative determination of drugs and metabolites in biological fluids. However, the common and early perception that utilization of HPLC-MS/MS practically guarantees selectivity is being challenged by a number of reported examples of lack of selectivity due to ion suppression or enhancement caused by the sample matrix and interferences from metabolites. In light of these serious method liabilities, questions about how to develop and validate reliable HPLC-MS/MS methods, especially for supporting long-term human pharmacokinetic studies, are being raised. The central issue is what experiments, in addition to the validation data usually provided for the conventional bioanalytical methods, need to be conducted to confirm HPLC-MS/MS assay selectivity and reliability. The current regulatory requirements include the need for the assessment and elimination of the matrix effect in the bioanalytical methods, but the experimental procedures necessary to assess the matrix effect are not detailed. Practical, experimental approaches for studying, identifying, and eliminating the effect of matrix on the results of quantitative analyses by HPLC-MS/MS are described in this paper. Using as an example a set of validation experiments performed for one of our investigational new drug candidates, the concepts of the quantitative assessment of the "absolute" versus "relative" matrix effect are introduced. In addition, experiments for the determination of, the "true" recovery of analytes using HPLC-MS/MS are described eliminating the uncertainty about the effect of matrix on the determination of this commonly measured method parameter. Determination of the matrix effect allows the assessment of the reliability and selectivity of an existing HPLC-MS/MS method. If the results of these studies are not satisfactory, the parameters determined may provide a guide to what changes in the method need to be made to improve assay selectivity. In addition, a direct comparison of the extent of the matrix effect using two different interfaces (a heated nebulizer, HN, and ion spray, ISP) under otherwise the same sample preparation and chromatographic conditions was made. It was demonstrated that, for the investigational drug under study, the matrix effect was clearly observed when ISP interface was utilized but it was absent when the HN interface was employed.
Contrary to common perceptions, the reliability of quantitative assays for the determination of drugs in biological fluids using high-performance liquid chromatography with tandem mass spectrometric (LC/MS/MS) detection methods and the integrity of resulting pharmacokinetic data may not be absolute. Results may be adversely affected by lack of specificity and selectivity due to ion suppression caused by the sample matrix, interferences from metabolites, and "cross-talk" effects. In this paper, an example of the effect of the sample matrix on the determination of finasteride (I) in human plasma is presented. The ion suppression effect was studied by analyzing standards of I injected directly in mobile phase and comparing the response (peak areas) of I and an internal standard (II) with the peak areas of the same analytes spiked before extraction into five different plasma pools and standards spiked into the plasma extracts after extraction. The LC/MS/MS analyses were performed using a turbo ion spray interface (TISP) under chromatographic conditions, characterized by minimal (total run time of 2 min, capacity factors, k' of 1.50 and 1.75 for I and II, respectively) and high retention of the analytes (total run time 6 min, k' of 3.25 and 13.25 for I and II, respectively). The absolute peak areas for I and II in different plasmas were calculated, and the slopes and peak area ratios at all concentrations within the standard curve ranges were compared. When analyses were performed under conditions of minimal HPLC retention, the slope of the standard line for one set of plasma samples was substantially different (about 50% higher) from that from other plasma sources. The precision of the assay, expressed as coefficient of variation (CV, %) was also inadequate and varied from 15 to 30% at all concentrations within the standard curve range. When the same experiments were repeated using high HPLC retention, the slopes from different plasma sources were practically the same, and the CV was improved to 6-14%. By increasing k' and providing more chromatographic retention of analytes, the "unseen" interferences from plasma matrix were mostly separated from analytes, practically eliminating the ion suppression. In addition, by eliminating from plasma extracts a number of endogenous components through more selective extraction, the ion suppression was also minimized. The detailed data and the design of these experiments are presented. In addition, development of a highly sensitive assay for I in human plasma at low picogram per milliliter concentrations using LC/MS/MS with a heated nebulizer (HN) interface, instead of a TISP interface, is described. In this case, the effects of sample matrixes were not observed.
Clinical studies were performed to examine the oral bioavailability of alendronate (4-amino-1-hydroxy-butylidene-1,1-bisphosphonate monosodium). All studies, with the exception of one performed in men, involved postmenopausal women. Short-term (24 to 36 hours) urinary recovery of alendronate after an intravenous dose of 125 to 250 micrograms averaged about 40% in both men and women. In women, oral bioavailability of alendronate was independent of dose (5 to 80 mg) and averaged (90% confidence interval) 0.76% (0.58, 0.98) when taken with water in the fasting state, followed by a meal 2 hours later. Bioavailability was similar in men [0.59%, (0.43, 0.81)]. Taking alendronate either 60 or 30 minutes before a standardized breakfast reduced bioavailability by 40% relative to the 2-hour wait. Taking alendronate either concurrently with or 2 hours after breakfast drastically (> 85%) impaired availability. Black coffee or orange juice alone, when taken with the drug, also reduced bioavailability (approximately 60%). Increasing gastric pH, by infusion of ranitidine, was associated with a doubling of alendronate bioavailability. A practical dosing recommendation, derived from these findings and reflective of the long-term nature of therapy for a disease such as osteoporosis, is that patients take the drug with water after an overnight fast and at least 30 minutes before any other food or beverage.
Postmenopausal women with established vertebral osteoporosis were studied for 2 years to determine the terminal elimination half-life and the duration of response to treatment with intravenous alendronate (30 mg) given over 4 days. The urinary excretion of alendronate followed a multiexponential decline. Approximately 50% of the total dose was excreted over the first 5 days, and a further 17% was excreted in the succeeding 6 months. Thereafter, there was a much slower elimination phase with an estimated mean terminal half-life of greater than 10 years (n ؍ 11). Urinary excretion of hydroxyproline and calcium decreased significantly from pretreatment values by day 3, reaching a nadir by 1 week (40% and 67% decrease, respectively). Thereafter, hydroxyproline remained suppressed for the following 2 years. In contrast, urinary calcium excretion returned gradually toward pretreatment values over the first year and during the second year was comparable to pretreatment values. Serum activity of alkaline phosphatase activity decreased over 3 months (23% reduction), increased gradually thereafter, and returned to pretreatment values at month 24. Bone mineral density measured at the spine increased by approximately 5% during the first year and remained significantly higher than pretreatment values at 2 years. We conclude that a short course of high doses of intravenous alendronate is associated with a prolonged skeletal retention of the agent. This open study also suggests that this regimen has a sustained effect on bone turnover persisting for at least 1
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.