Sickle cell anemia and thalassemia are hemoglobinopathies rarely encountered in the United States. Compounded with congenital heart disease, patients with sickle cell disease (SCD) requiring cardiopulmonary bypass and open-heart surgery represent the proverbial "needle in the haystack". As such, there is some trepidation on the part of clinicians when these patients present for complex cardiac surgery. SCD is an autosomal, recessive condition that results from a single nucleotide polymorphism in the β-globin gene. Hemoglobin SS molecules (HgbSS) with this point mutation can polymerize under the right conditions, stiffening the erythrocyte membrane and distorting the cellular structure to the characteristic sickle shape. This shape change alters cellular transit through the microvasculature. As a result, circumstances such as hypoxia, hypothermia, acidosis or diminished blood flow can lead to aggregation, vascular occlusion and thrombosis. Chronically, SCD can give rise to multiorgan damage secondary to hemolysis and vascular obstruction. This review and case study details an 11-year-old African-American male with known SCD who presented to the cardiothoracic surgical service with congenital heart disease consisting of an anomalous, intramural right coronary artery arising from the left coronary sinus for surgical consultation and subsequent surgical correction. This case report will include a review of the pathophysiology and current literature regarding preoperative, intraoperative and postoperative management of SCD patients.
Mechanical circulatory support emerged for the pediatric population in the late 1980s as a bridge to cardiac transplantation. The Total Artificial Heart (TAH-t) (SynCardia Systems Inc., Tuscon, AZ) has been approved for compassionate use by the Food and Drug Administration for patients with end-stage biventricular heart failure as a bridge to heart transplantation since 1985 and has had FDA approval since 2004. However, of the 1,061 patients placed on the TAH-t, only 21 (2%) were under the age 18. SynCardia Systems, Inc. recommends a minimum patient body surface area (BSA) of 1.7 m(2), thus, limiting pediatric application of this device. This unique case report shares this pediatric institution's first experience with the TAH-t. A 14-year-old male was admitted with dilated cardiomyopathy and severe biventricular heart failure. The patient rapidly decompensated, requiring extracorporeal life support. An echocardiogram revealed severe biventricular dysfunction and diffuse clot formation in the left ventricle and outflow tract. The decision was made to transition to biventricular assist device. The biventricular failure and clot formation helped guide the team to the TAH-t, in spite of a BSA (1.5 m(2)) below the recommendation of 1.7 m(2). A computed tomography (CT) scan of the thorax, in conjunction with a novel three-dimensional (3D) modeling system and team, assisted in determining appropriate fit. Chest CT and 3D modeling following implantation were utilized to determine all major vascular structures were unobstructed and the bronchi were open. The virtual 3D model confirmed appropriate device fit with no evidence of compression to the left pulmonary veins. The postoperative course was complicated by a left lung opacification. The left lung anomalies proved to be atelectasis and improved with aggressive recruitment maneuvers. The patient was supported for 11 days prior to transplantation. Chest CT and 3D modeling were crucial in assessing whether the device would fit, as well as postoperative complications in this smaller pediatric patient.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2025 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.