This randomized, comparative study assessed the long-term efficacy and tolerability of thymoglobulin (TMG) induction in 93 liver transplant patients with an initial regimen of tacrolimus (Tac), mycophenolate mofetil (MMF), and steroids. Forty-four patients were randomly allocated to the TMGϩ group, and 49 patients were randomly allocated to the TMGϪ group. In both groups, Tac was given orally at the initial daily dose of 0.075 mg/kg twice daily, and MMF was given at the initial daily dose of 2 g/day. Steroid withdrawal was planned at 3 months after liver transplantation. The results were evaluated with respect to acute rejection incidence, patient and graft survival, graft function, and medical complications until 5 years or death for all patients. No significant differences were found between groups for the incidence of acute rejection at 5 years (11.4% versus 14.3%), 5-year patient survival (77.3% versus 87.8%), graft function, or postoperative renal function. One patient in the TMGϪ group underwent retransplantation. There was no difference between groups with respect to the incidence of medical complications, excepted for a higher rate of leukopenia in the TMGϩ group, during the 5-year follow-up. In conclusion, the results of this prospective randomized study suggest that the addition of TMG to a triple immunosuppressive regimen (Tac, MMF, and steroids) did not modify the incidence of acute rejection episodes or long-term survival and was responsible for increased leukopenia rates.
Unresectable liver tumors are often treated with interstitial probes that modify tissue temperature, and efficacious treatment relies on image guidance for tissue targeting and assessment. Here, we report the in vivo evaluation of an interstitial applicator with a mechanically oscillating five-element dual-mode transducer. After thoroughly characterizing the transducer, tissue response to high-intensity ultrasound was numerically calculated to select parameters for experimentation in vivo. Using perfused porcine liver, B-mode sector images were formed before and after a 120-s therapy period, and M-mode imaging monitored the therapy axis during therapy. The time-averaged transducer surface intensity was 21 or 27 W/cm (2). Electroacoustic conversion efficiency was maximally 72 +/- 3% and impulse response length was 295 +/- 1.0 ns at -6 dB. The depth of thermal damage measured by gross histology ranged from 10 to 25 mm for 13 insertion sites. For six sites, M-mode data exhibited a reduction in gray-scale intensity that was interpreted as the temporal variation of coagulation necrosis. Contrast ratio analysis indicated that the gray-scale intensity dropped by 7.8 +/- 3.3 dB, and estimated the final lesion depth to an accuracy of 2.3 +/- 2.4 mm. This paper verified that the applicator could induce coagulation necrosis in perfused liver and demonstrated the feasibility of real-time monitoring.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.