This assignment applies to all translations of the Work as well as to preliminary display/posting of the abstract of the accepted article in electronic form before publication. If any changes in authorship (order, deletions, or additions) occur after the manuscript is submitted, agreement by all authors for such changes must be on file with the Publisher. An author's name may be removed only at his/her written request. (Note: Material prepared by employees of the US government in the course of their official duties cannot be copyrighted.
Purpose. Bone atrophy after tooth loss may leave insufficient bone for implant placement. We compared volumetric changes after autogenous ramus block bone grafting (RBG) or guided bone regeneration (GBR) in horizontally deficient maxilla before implant placement. Materials and Methods. In this retrospective study, volumetric changes at RBG or GBR graft sites were evaluated using cone-beam computed tomography. The primary outcome variable was the volumetric resorption rate. Secondary outcomes were bone gain, graft success, and implant insertion torque. Results. Twenty-four patients (28 grafted sites) were included (GBR, 15; RBG, 13). One patient (RBG) suffered mucosal dehiscence at the recipient site 6 weeks after surgery, which healed spontaneously. Mean volume reduction in the GBR and RBG groups was 12.48 ± 2.67% and 7.20 ± 1.40%, respectively. GBR resulted in significantly more bone resorption than RBG (P < 0.001). Mean horizontal bone gain and width after healing were significantly greater in the GBR than in the RBG group (P = 0.002 and 0.005, resp.). Implant torque was similar between groups (P > 0.05). Conclusions. Both RBG and GBR hard-tissue augmentation techniques provide adequate bone graft volume and stability for implant insertion. However, GBR causes greater resorption at maxillary augmented sites than RBG, which clinicians should consider during treatment planning.
Extensive alveolar bone resorption because of pneumatized maxillary sinus is a common problem that limits dental implant placement. Maxillary sinus floor augmentation (MSFA) is an accepted treatment protocol that provides sufficient bone volume. The aim of this study was to evaluate the percentage of graft volume reduction following MSFA using cone beam computed tomography. In this retrospective study, cone beam computed tomography scans of MSFA were measured to evaluate the volume of the grafted sinus with deproteinized bovine bone (DBB), mineralized allograft (MA), or a mixture of MA and demineralized allograft as a composite. The volumetric changes in sinus augmentation between 2 weeks (T-I) and 6 months (T-II) after operation were analyzed. Thirty-nine patients were included in this study. The average percent volume reduction was 8.14 ± 3.76%, 19.38 ± 9.22%, and 24.66 ± 4.68% for DBB, MA, and composite graft, respectively. A significant graft volume reduction was found between T-I and T-II for all groups (P < 0.01). The DBB group showed the least volume reduction (P < 0.01). Biomaterials can influence the bone graft volume change before implant placement. Deproteinized bovine bone may offer greater volume stability during healing than mineralized and composite allografts.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.