The conduct of anesthesia in morbidly obese patients undergoing neurosurgical procedures can be challenging considering the multi-system organ involvement. Implementation of conventional lung-protective ventilation in morbidly obese patients can have a negative impact on the intra-cranial dynamics. We report a series of three patients with morbid obesity and a difficult airway for the neurosurgical procedure. The patients were oxygenated with high-flow oxygen devices to ensure an adequate oxygen reserve in the peri-operative period. A modified intra-operative lung-protective ventilation with normocarbia was implemented with no impact on the intra-cranial pressure in the prone position in two of the patients. Oxygenation with high-flow devices should be considered during the peri-operative period in morbidly obese patients to avert an adverse respiratory event, and a modified lung-protective ventilation technique is feasible with normal intra-cranial dynamics intra-operatively.
This article has been accepted for publication and has undergone full peer review but has not been through the copyediting, typesetting, pagination, and proofreading processes, which may lead to differences between this version and the version of record.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.