Objective In the presurgical workup of MRI-negative (MRI−, or “nonlesional”) pharmacoresistant focal epilepsy (PFE) patients, discovering a previously undetected lesion can drastically change the evaluation and likely improve surgical outcome. Our study utilizes a voxel-based MRI post-processing technique, implemented in a morphometric analysis program (MAP), to facilitate detection of subtle abnormalities in a consecutive cohort of MRI− surgical candidates. Methods Included in this retrospective study was a consecutive cohort of 150 MRI-surgical patients. MAP was performed on T1-weighted MRI, with comparison to a scanner-specific normal database. Review and analysis of MAP were performed blinded to patients’ clinical information. The pertinence of MAP+ areas was confirmed by surgical outcome and pathology. Results MAP showed a 43% positive rate, sensitivity of 0.9 and specificity of 0.67. Overall, patients with MAP+ region completely resected had the best seizure outcomes, followed by the MAP− patients, and patients who had no/partial resection of the MAP+ region had the worst outcome (p<0.001). Subgroup analysis revealed that visually identified subtle findings are more likely correct if also MAP+. False-positive rate in 52 normal controls was 2%. Surgical pathology of the resected MAP+ areas contained mainly non-balloon-cell FCD. Multiple MAP+ regions were present in 7% of patients. Conclusions MAP can be a practical and valuable tool to: (1) guide the search for subtle MRI abnormalities, and (2) confirm visually identified questionable abnormalities in patients with PFE due to suspected FCD. A MAP+ region, when concordant with the patient’s electro-clinical presentation, should provide a legitimate target for surgical exploration.
) for a scientific commentary on this article.Magnetoencephalography and stereo-electroencephalography are often necessary in the course of the non-invasive and invasive presurgical evaluation of challenging patients with medically intractable focal epilepsies. In this study, we aim to examine the significance of magnetoencephalography dipole clusters and their relationship to stereo-electroencephalography findings, area of surgical resection, and seizure outcome. We also aim to define the positive and negative predictors based on magnetoencephalography dipole cluster characteristics pertaining to seizure-freedom. Included in this retrospective study were a consecutive series of 50 patients who underwent magnetoencephalography and stereo-electroencephalography at the Cleveland Clinic Epilepsy Center. Interictal magnetoencephalography localization was performed using a single equivalent current dipole model. Magnetoencephalography dipole clusters were classified based on tightness and orientation criteria. Magnetoencephalography dipole clusters, stereo-electroencephalography findings and area of resection were reconstructed and examined in the same space using the patient's own magnetic resonance imaging scan. Seizure outcomes at 1 year postoperative were dichotomized into seizurefree or not seizure-free. We found that patients in whom the magnetoencephalography clusters were completely resected had a much higher chance of seizure-freedom compared to the partial and no resection groups (P = 0.007). Furthermore, patients had a significantly higher chance of being seizure-free when stereo-electroencephalography completely sampled the area identified by magnetoencephalography as compared to those with incomplete or no sampling of magnetoencephalography results (P = 0.012). Partial concordance between magnetoencephalography and interictal or ictal stereo-electroencephalography was associated with a much lower chance of seizure freedom as compared to the concordant group (P = 0.0075). Patients with one single tight cluster on magnetoencephalography were more likely to become seizure-free compared to patients with a tight cluster plus scatter (P = 0.0049) or patients with loose clusters (P = 0.018). Patients whose magnetoencephalography clusters had a stable orientation perpendicular to the nearest major sulcus had a better chance of seizure-freedom as compared to other orientations (P = 0.042). Our data demonstrate that stereo-electroencephalography exploration and subsequent resection are more likely to succeed, when guided by positive magnetoencephalography findings. As a corollary, magnetoencephalography clusters should not be ignored when planning the stereo-electroencephalography strategy. Magnetoencephalography tight cluster and stable orientation are positive predictors for a good seizure outcome after resective surgery, whereas the presence of scattered sources diminishes the probability of favourable outcomes. The concordance pattern between magnetoencephalography and stereo-electroencephalography is a strong...
Automated surface-based MRI morphometry equipped with machine learning showed robust performance across cohorts from different centers and scanners. The proposed method may be a valuable tool to improve FCD detection in presurgical evaluation for patients with pharmacoresistant epilepsy.
Objective: Ultra-high-field 7-Tesla (7T) magnetic resonance imaging (MRI) offers increased signal-to-noise and contrast-to-noise ratios, which may improve visualization of cortical malformations. We aim to assess the clinical value of in vivo structural 7T MRI and its post-processing for the noninvasive identification of epileptic brain lesions in patients with pharmacoresistant epilepsy and nonlesional 3T MRI who are undergoing presurgical evaluation. Methods: Sixty-seven patients were included who had nonlesional 3T MRI by official radiology report. Epilepsy protocols were used for the 3T and 7T acquisitions. Post-processing of the 7T T1-weighted magnetization-prepared two rapid acquisition gradient echoes sequence was performed using the morphometric analysis program (MAP) with comparison to a normal database consisting of 50 healthy controls. Review of 7T was performed by an experienced board-certified neuroradiologist and at the multimodal patient management conference. The clinical significance of 7T findings was assessed based on intracranial electroencephalography (ICEEG) ictal onset, surgery, postoperative seizure outcomes, and histopathology. Results: Unaided visual review of 7T detected previously unappreciated subtle lesions in 22% (15/67). When aided by 7T MAP, the total yield increased to 43% (29/67). The location of the 7T-identified lesion was identical to or contained within the ICEEG ictal onset in 13 of 16 (81%). Complete resection of the 7T-identified lesion was associated with seizure freedom (P = .03). Histopathology of the 7T-identified lesions encountered mainly focal cortical dysplasia (FCD). 7T MAP yielded 25% more lesions (6/24) than 3T MAP, and showed improved conspicuity in 46% (11/24). Significance: Our data suggest a major benefit of 7T with post-processing for detecting subtle FCD lesions for patients with pharmacoresistant epilepsy and nonlesional 3T MRI.
Background Conventional MRI can be limited in detecting subtle epileptic lesions or identifying active/epileptic lesions among widespread, multifocal lesions. Purpose We developed a high‐resolution 3D MR fingerprinting (MRF) protocol to simultaneously provide quantitative T1, T2, proton density, and tissue fraction maps for detection and characterization of epileptic lesions. Study type Prospective. Population National Institute of Standards and Technology (NIST) / International Society for Magnetic Resonance in Medicine (ISMRM) phantom, five healthy volunteers and 15 patients with medically intractable epilepsy undergoing presurgical evaluation with noninvasive or invasive electroclinical data. Field Strength/Sequence 3D MRF scans and routine clinical epilepsy MR protocols were acquired at 3 T. Assessment The accuracy of the T1 and T2 values were first evaluated using the NIST/ISMRM phantom. The repeatability was then estimated with both phantom and volunteers based on the coefficient of variance (CV). For epilepsy patients, all the maps were qualitatively reviewed for lesion detection by three independent reviewers (S.E.J., M.L., I.N.) blinded to clinical data. Region of interest (ROI) analysis was performed on T1 and T2 maps to quantify the multiparametric signal differences between lesion and normal tissues. Findings from qualitative review and quantitative ROI analysis were compared with patients' electroclinical data to assess concordance. Statistical Tests Phantom results were compared using R‐squared, and patient results were compared using linear regression models. Results The phantom study showed high accuracy with the standard values, with an R2 of 0.99. The volunteer study showed high repeatability, with an average CV of 4.3% for T1 and T2 in various tissue regions. For the 15 patients, MRF showed additional findings in four patients, with the remaining 11 patients showing findings consistent with conventional MRI. The additional MRF findings were highly concordant with patients' electroclinical presentation. Data Conclusion The 3D MRF protocol showed potential to identify otherwise inconspicuous epileptogenic lesions from the patients with negative conventional MRI diagnosis, as well as to correlate with different levels of epileptogenicity when widespread lesions were present. Level of Evidence: 3. Technical Efficacy Stage: 3. J. Magn. Reson. Imaging 2019;49:1333–1346.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.