With regard to measuring nitrous oxide (N 2 O) emissions from biological sources, there are three most widely adopted methods that use gas chromatograph with an electron capture detector (GC-ECD). They use: (a) nitrogen (N 2 ) as the carrier gas (DN); (b) ascarite as a carbon dioxide (CO 2 ) trap with DN (DN-Ascarite); and (c) a mixture gas of argon and methane as the carrier (AM). Additional methods that use either a mixture of argon and methane (or of CO 2 and N 2 ) as a make-up gas with the carrier nitrogen or soda lime (or ascarite) as a CO 2 trap with the carrier helium have also been adopted in a few studies. To test the hypothesis that the use of DN sometimes considerably biases measurements of N 2 O emissions from plants, soils or soil-plant systems, experiments were conducted involving DN, AM and DN-Ascarite. When using DN, a significant relationship appeared between CO 2 concentrations and the apparent N 2 O concentrations in air samples. The use of DN led to significantly overestimated N 2 O emissions from detached fresh plants in static chamber enclosures. Meanwhile, comparably lower emissions were found when using either the DN-Ascarite or AM methods. When an N 2 O flux (from a soil or a soil-plant system), measured by DN in combination with sampling from the enclosure of a static opaque chamber, was greater than 200 μg N m −2 h −1 , no significant difference was found between DN and DN-Ascarite. When the DN-measured fluxes were within the ranges of <−30, −30-0, 0-30, 30-100 and 100-200 μg N m −2 h −1 , significant differences that amounted to −72, −22, 5, 38 and 64 μg N m −2 h −1 , respectively, appeared in comparison to DN-Ascarite. As a result, the DN measurements in rice-wheat and Plant Soil (vegetable fields overestimated both annual total N 2 O emissions (by 7-62%, p<0.05) and direct emission factors for applied nitrogen (by 6-65%). These results suggest the necessity of reassessing the available data determined from DN measurements before they are applied to inventory estimation. Further studies are required to explore appropriate approaches for the necessary reassessment. Our results also imply that the DN method should not be adopted for measuring N 2 O emissions from weak sources (e.g., with intensities less than 200 μg N m −2 h −1 ). In addition, we especially do not recommend the use of DN to simultaneously measure N 2 O and CO 2 with the same ECD.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.