Exposure to airborne agents needs to be assessed in the personal breathing zone by the use of personal measurement equipment. Specific measurement devices for assessing personal exposure to airborne nanomaterials have only become available in the recent years. They can be differentiated into direct-reading personal monitors and personal samplers that collect the airborne nanomaterials for subsequent analyses. This article presents a review of the available personal monitors and samplers and summarizes the available literature regarding their accuracy, comparability and field applicability. Due to the novelty of the instruments, the number of published studies is still relatively low. Where applicable, literature data is therefore complemented with published and unpublished results from the recently finished nanoIndEx project. The presented data show that the samplers and monitors are robust and ready for field use with sufficient accuracy and comparability. However, several limitations apply, e.g. regarding the particle size range of the personal monitors and their in general lower accuracy and comparability compared with their stationary counterparts. The decision whether a personal monitor or a personal sampler shall be preferred depends strongly on the question to tackle. In many cases, a combination of a personal monitor and a personal sampler may be the best choice to obtain conclusive results.
Despite compelling reports on asbestos-like pathogenicity, regulatory bodies have been hesitant to implement fiber number-based exposure limits for biodurable nanoscale fibers. One reason has been the lack of a practicable strategy for assessing airborne fiber number concentrations. Here, a method is proposed, detailed and tested for compliance checking concentrations of airborne nano- and microscale fibers. It relies on Poisson statistical significance testing of the observed versus a predicted number of fibers on filters that have sampled a known volume of aerosol. The prediction is based on the exposure concentration to test. Analogous to the established counting rules for WHO-fibers, which use a phase contrast microscopy-related visibility criterion of 200 nm, the new method also introduces a cut-off diameter, now at 20 nm, which is motivated by toxicological findings on multi-walled carbon nanotubes. This cut-off already reduces the workload by a factor of 400 compared to that necessary for imaging, detecting and counting nanofibers down to 1 nm in diameter. Together with waiving any attempt to absolutely quantify fiber concentrations, a compliance check at the limit-of-detection results in an analytical workload that renders our new approach practicable. The proposed method was applied to compliance checking in 14 very different workplaces that handled or machined nanofiber-containing materials. It achieved detecting violations of the German benchmark exposure level of 10,000 nanofibers per cubic meter.
The assessment of the toxicity of airborne nanofibers is an important task. It relies on toxicological inhalation studies and validated exposure measurement techniques. Both require nanofiber-containing aerosols of known morphological composition and controlled fraction of individual fibers. Here, a dry powder dispersion method is presented that operates with mixtures of nanofibers and microscale beads. Aerosolization experiments of mixtures of multi-walled carbon nanotubes (MWCNTs) and glass beads that were continuously fed into a Venturi nozzle enabled high generation rates of aerosols composed of individual and agglomerate nanofiber structures. The aerosol process achieved good stability over more than 2 h with respect to concentration and aerodynamic size distribution. Its operation duration is limited only by the reservoir volume of the cyclone used to separate the beads from the aerosol. The aerosol concentration can be controlled by changing the mass ratio of MWCNTs and glass beads or by adapting the mass feed rate to the nozzle. For two agglomerated MWCNT materials, aerosol concentrations ranged from 1700 to 64,000 nano-objects per cm3. Comprehensive scanning electron microscope analysis of filter samples was performed to categorize and determine the morphological composition of the aerosol, its fiber content as well as fiber length and diameter distributions. High fractions of individual fibers of up to 34% were obtained, which shows the setup to be capable of dispersing also highly tangled MWCNT agglomerates effectively.Electronic supplementary materialThe online version of this article (10.1007/s11051-018-4262-y) contains supplementary material, which is available to authorized users.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.