Background: The purpose of this research was to investigate the effects of disinfection and three different sterilization methods on the dimensional changes and mechanical properties of three-dimensional (3D) printed surgical guide for implant therapy. The objective was to assess the effects of sterilization procedures in 3D printed drill guide templates with destructive and non-destructive material testing. Methods: Fifteen identical drill guide templates were produced using a 3D printer. The surgical guides were classified into five groups: three controls, three disinfected (4% Gigasept®, 60 min), three plasma sterilized, three autoclave sterilized (+ 1 bar, 121°C, 20 min), and three autoclave sterilized (+ 2 bar, 134°C, 10 min). The templates were digitalized with a Steinbichler SCAN ST 3D scanner. Length was measured under an SZX16 stereomicroscope. A scanning electron microscope was used to study the surface morphology of the drill templates. The hardness, and flexural and compressive strength were measured to assess any changes in the physical characteristics of the material caused by sterilization. The drill guide templates were also examined with a Dage XiDAT 6600 X-ray. During the X-ray examinations, the following parameters were used: 100 kV voltage, 128 AVG averaging, 0.8 W power. One-way analysis of variance (ANOVA) was used to detect the difference between groups. Results: Evaluation of the hardness measurements of the various specimens shows that the hardness of the material was not changed by the plasma sterilization (p = 0.0680), steam sterilization on 121°C (p = 0.6033) or disinfection process (p = 0.1399). The statistical analysis revealed significant difference in hardness strength of the autoclave sterilized (134°C) specimens (p = 0.0002). There was no significant difference between the goups regarding the scanning electron microscopic and stereomicroscopic examinations. There was no significant difference regarding the X-ray visibility of the templates to the effect of the disinfection (p = 0.7844), plasma sterilization (p = 0.4091) and steam sterilization on 121°C (p = 0.9277) and steam sterilization on 131°C (p = 0.093). The effect of the sterilization was the same in case of both flexural and compressive strength of the material. Conclusions: Our findings indicate that plasma sterilization and steam sterilization at 121°C were both suitable for sterilizing the tested 3D printed surgical guides.
BackgroundKnowledge about the health effects of e-cigarette use (or vaping) among past and current combustible cigarette users is limited. Several studies have assessed vaping-related adverse events (AEs) and beneficial health effects, however, most studies focused on AEs in general and examined only a few physiological changes that vapers experience. This study aims to explore self-reported AEs and perceived health changes due to e-cigarette use among Hungarian adult e-cigarette-only users (former smokers who switched completely to e-cigarette use) and dual users (smokers who use e-cigarettes and combustible tobacco cigarettes concomitantly).MethodsA cross-sectional, web-based survey of 1042 adult Hungarian e-cigarette users was conducted in 2015. Participants reported AEs and changes in physiological functions since they switched from smoking to e-cigarette use or while dually using e-cigarettes and combustible cigarettes. Confirmatory factor analysis with covariates was applied to explain perceived health changes due to e-cigarette-only use and dual use.ResultsDual users (17.6%) were significantly more likely to report AEs of vaping than e-cigarette-only users (26.2% vs. 11.8%, p < 0.001). Experiencing health improvements were significantly more likely among e-cigarette-only users than for dual users for all surveyed physiological functions. E-cigarette-only users reported larger effects of vaping on sensory, physical functioning, and mental health factors compared to dual users. Self-reported changes in sensory and physical functioning were significantly higher among individuals using e-cigarettes more than a year and people who were past heavy smokers (smoked ≥20 cigarettes per day). Gender was related to sensory improvement only; males reported greater improvement than females.ConclusionsThe majority of e-cigarette-only users reported more perceived beneficial changes in physiological functions and fewer AEs than dual users. Perceived short-term benefits of e-cigarette use may reinforce users despite the uncertainty of long-term health consequences. Health professionals should provide balanced information regarding the possible short- and long-term positive and negative health effects of e-cigarette use during consultations with patients.Electronic supplementary materialThe online version of this article (10.1186/s12889-019-6629-0) contains supplementary material, which is available to authorized users.
Objective: Increasing evidence indicates that different neuropeptide-containing nerve elements are involved in the immune system and influence the inflammation of the gastrointestinal tract. The aim of this study was to investigate the morphological localization and distribution of the different immunoreactive (IR) nerve fibers and immunocompetent cells in the oral mucosa (e.g. tongue, gingiva) and compare the results with data received from streptozotocin (STZ)-induced diabetic rats. Materials and Methods: The different nerve elements and immunocytes were detected by ABC immunohistochemistry. Results: The IR nerve fibers were found in the tunica propria of oral mucosa with different densities. These IR nerve fibers were mainly located beneath the epithelial lining, around the blood vessels and glands, and some of them were also located in the taste buds. After 2 weeks of STZ treatment the total number of IR nerve fibers, especially the SP and neuropeptide Y (NPY) IR ones, was significantly increased (p < 0.05), as was also the number of immunocytes (lymphocytes, plasma cells, mast cells). Some of these cells also showed immunoreactivity for substance P (SP) and NPY. In several cases the SP IR nerve fibers were found in close proximity to the immunocytes. Electron microscopic investigation also revealed the close association between the IR nerve fibers and immunocompetent cells where the gap was 1 µm or even less. Conclusions: The close anatomical associations suggest communication between nerve fibers and immune cells which can be crucial for maintaining mucosal homeostasis and for ensuring an appropriate response to injury.
Dental amalgam has been used for more than 150 years due to its beneficial mechanical properties and durability in dentistry. In the past and to date, many questions about amalgam restorations have arisen, especially regarding the mercury content, which has been the subject of global disputes. By presenting the past and present of the ‘amalgam issue’, the aim of our paper is to display the current position of international literature. This summary is based on the publications in the PubMed database, the guidelines of the Council of European Dentists. Although the use of dental amalgam is widespread, concerns have been raised about the adverse effect on human health and the environment, focusing on its heavy metal pollution during waste treatment. In 2017, the European Union (EU) adopted the so-called Mercury Regulation, based on the United Nations Minamata Convention on Mercury, the recommendations of which are presented in the present review. This Regulation includes the requirement for EU Member States to develop a national action plan for the phase-down of amalgam. The feasibility plan for complete phase-out may be guaranteed by 2030. The authors discuss the advantages and disadvantages of possible amalgam alternatives by presenting glass-ionomers and resin-based composites. In the future, more material research programmes and long-term follow-up studies are necessary. In addition to several global health organizations, the Council of European Dentists also draws attention to prevent dental caries, expecting to reduce the number of restorations. Orv Hetil. 2018; 159(42): 1700–1709.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.