Background-The crucial function of hepatic lipase (HL) in lipid metabolism has been well established, but the relationship between HL activity and coronary artery disease (CAD) is disputed. Methods and Results-We measured HL activity in the postheparin plasma of 200 consecutive men undergoing elective coronary angiography and determined the degree of CAD with the extent score, which has been shown to be better correlated with known risk factors than other measures of CAD extent. We found a significant inverse correlation between HL activity and the extent of CAD (rϭϪ0.19, PϽ0.01). This association was mainly due to patients with HDL levels Ͼ0.96 mmol/L (nϭ94, rϭϪ0.30, PϽ0.005). HL activity was lower in 173 patients with CAD than in 40 controls with normal angiograms (286Ϯ106 versus 338Ϯ108 nmol · mL Ϫ1 · min
SummaryBackground and objectives Double-chamber peritoneal dialysis fluids exert less toxicity by their neutral pH and reduced glucose degradation product content. The role of the buffer compound (lactate and bicarbonate) has not been defined in humans.Design, setting, participants, & measurements A multicenter randomized controlled trial in 37 children on automated peritoneal dialysis was performed. After a 2-month run-in period with conventional peritoneal dialysis fluids, patients were randomized to neutral-pH, low-glucose degradation product peritoneal dialysis fluids with 35 mM lactate or 34 mM bicarbonate content. Clinical and biochemical monitoring was performed monthly, and peritoneal equilibration tests and 24-hour clearance studies were performed at 0, 3, 6, and 10 months.Results No statistically significant difference in capillary blood pH, serum bicarbonate, or oral buffer supplementation emerged during the study. At baseline, peritoneal solute equilibration and clearance rates were similar. During the study, 4-hour dialysis to plasma ratio of creatinine tended to increase, and 24-hour dialytic creatinine and phosphate clearance increased with lactate peritoneal dialysis fluid but not with bicarbonate peritoneal dialysis fluid. Daily net ultrafiltration, which was similar at baseline (lactate fluid=5.462.6 ml/g glucose exposure, bicarbonate fluid=4.961.9 ml/g glucose exposure), decreased to 4.661.0 ml/g glucose exposure in the lactate peritoneal dialysis fluid group, whereas it increased to 5.161.7 ml/g glucose exposure in the bicarbonate content peritoneal dialysis fluid group (P=0.006 for interaction).Conclusions When using biocompatible peritoneal dialysis fluids, equally good acidosis control is achieved with lactate and bicarbonate buffers. Improved long-term preservation of peritoneal membrane function may, however, be achieved with bicarbonate-based peritoneal dialysis fluids.
Subcutaneous injections of darbepoetin-alpha are more painful than those of epoetin-beta in the majority of paediatric patients. The observed difference in painfulness is related to the nature of the injected compounds and may limit the subcutaneous applicability of darbepoetin-alpha in children.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.